ArbNation Join free

Buried lines at stump jobs: pipeline damage reporting, line markers and HSE guidance

US pipeline rules require an excavator to report any damage to the operator and to call 911 for a release. Line markers carry a warning word, the pipeline name and an operator phone number. HSE's HSG47 covers gas, power and telecom cables in Britain.

Checked against the sources at the bottom of this page on October 21, 2026. Rules, fees and pay change: the source has the last word.

This page reports what the official source says. It is not legal advice: ask the office named here. It draws on two parts of the US Code of Federal Regulations, 49 CFR Part 196 Subpart B and 49 CFR 192.707, and on HSE's guidance HSG47, Avoiding danger from underground services. Calling before digging is covered in the guide to call before you dig.

United States: damage prevention, 49 CFR Part 196 Subpart B

Subpart B sets the minimum requirements for excavators to protect pipelines under PHMSA or State pipeline safety rules from excavation damage. Section 196.103 requires an excavator, before and during excavation, to use an available one-call system to notify pipeline operators of the timing and location of the dig. If pipelines exist in the area, the excavator waits for the operator to arrive and mark the pipeline facilities before excavating. The excavator works with proper regard for the marks, taking all practicable steps to prevent damage, and uses one-call again as needed.

Section 196.107 covers damage. If a pipeline is damaged in any way by excavation, the excavator must promptly report it to the pipeline operator, whether or not a leak occurs, at the earliest practicable moment after discovering it. Section 196.109 covers a release. If the damage releases PHMSA-regulated natural or other gas, or a hazardous liquid, the excavator must promptly report the release to emergency response authorities by calling 911. Section 196.111 lets PHMSA enforce its existing requirements against an operator that fails to respond to a locate request or to mark its pipeline accurately.

United States: pipeline line markers, 49 CFR 192.707

Section 192.707 covers markers for gas mains and transmission lines. A marker is placed and maintained as close as practical over each buried main and transmission line at each public road and railroad crossing, and wherever necessary to identify the line and reduce the chance of damage. Lines aboveground in areas accessible to the public are marked along each section. The exceptions include offshore lines and crossings of waterways, and mains in Class 3 or Class 4 locations where a damage prevention program is in effect.

The wording on a marker is set out in the rule. It reads "Warning", "Caution" or "Danger", then "Gas (or name of gas transported) Pipeline". Outside heavily developed urban areas those letters are at least 1 inch (25 millimeters) high with a 1/4 inch (6.4 millimeters) stroke, on a sharply contrasting background. The marker also shows the operator's name and a telephone number, with area code, where the operator can be reached at all times.

Great Britain: HSE guidance HSG47

HSG47 is aimed at everyone involved in commissioning, planning, managing and carrying out work on or near underground services. It will also be of use to the owners and operators of those services. HSE describes three basic elements of a safe system of work during excavation: planning the work, locating and identifying buried services, and safe excavation. The guide describes how damage hurts people differently by service type.

  • Electricity cables: injuries usually come from the explosive effects of arcing current and any fire when a live cable is penetrated by a sharp object such as the point of a tool. HSE calls the injuries severe and potentially fatal burns to the hands, face and body. Electric shock is possible but less likely.
  • Gas pipes: damage can cause an immediate leak or a leak some time later, which may lead to fire or explosion. Leaking LPG is a greater risk than natural gas because it is heavier than air and does not disperse readily.
  • Telecommunication and TV cables: the risk of injury to workers is normally very low, but flammable and toxic gases can enter ducts and gather in chambers and manholes.

For a suspected gas leak, HSG47 lists evacuating everyone from the immediate vicinity and warning occupants of any building whose service connection is damaged. The list goes on with telephoning the National Gas Emergency number, 0800 111 999, and prohibiting smoking and extinguishing all naked flames and other ignition sources within at least 5 m of the leak. It also says any damage, however slight, is reported to the owner. When an excavator strikes a cable, HSG47 says drivers stay in the cab, because they may be electrocuted if they climb down, and no one approaches the cable until its owner has made it safe.

HSG47 says the depth of cover for gas mains is normally about 750 mm in a roadway and about 600 mm in a footway. For service connections it is normally about 450 mm in both roads and footways. High-pressure transmission pipelines are usually buried with at least 900 mm of cover. HSG47 adds that depths should never be assumed, because pipes may be found at shallower depths. It also says mechanical excavators are not used within 500 mm of a gas pipe.

HSG47 names the markers used on gas services: marker tiles, coloured plastic markers including those for PE mains, and marker posts or plates that may show the position and size of valves or test points. These may have been disturbed, so HSE says they are not relied on as an accurate indicator of position. Pipeline marker posts are also listed among the signs that underground services exist. The lack of such signs does not mean there are no underground services.

Sources