ArbNation Join free

Defensible space and fuel reduction: Oregon's model code, OSU zones and NFPA 1144

Oregon's State Fire Marshal publishes a model defensible space code for local governments and a zone guide that starts with the first five feet around a home. Oregon State University and NFPA 1144 draw the zones and scope differently.

Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.

This page reports what the official source says. It is not legal advice: ask the office named here. It draws on the Oregon State Fire Marshal's defensible space page, Oregon State University Extension publication EM 9184 and the listing of NFPA 1144, 2018 edition. Wildfire clearing rules in other places have their own pages, such as the Oregon wildfire plan page.

The Oregon State Fire Marshal's program and model code

The Oregon State Fire Marshal runs a Defensible Space Program with free defensible space assessments. The assessment is an education-focused visit that gives home and property owners tips to start or improve their defensible space.

The Fire Marshal and its partners developed a model defensible space code that local governments across Oregon can adopt. The office calls it a baseline safety standard that communities can expand on. Under OAR 837-040-0030, a local government pursuing adoption of the model code notifies the State Fire Marshal.

The three zones on the Fire Marshal's page

Defensible space zones on the Oregon State Fire Marshal page
ZoneItems listed
The homeRoof and gutters free of leaves, needles and debris. Attic and crawlspace vents covered with 1/8 inch metal wire mesh. Metal gates for fence sections within five feet of the house.
0 to 5 feet, immediate zoneRiver rock, gravel or pavers. Bark mulch and flammable plants such as junipers removed. Debris cleared from below decks and patios.
5 to 30 feet, intermediate zoneGrass mowed to less than 4 inches. Tree crowns spaced at least 10 feet apart. Trees pruned up 6 feet from the ground.
30 to 100 feet and beyond, extended zoneLadder fuels, meaning brush under trees, removed. Heavy ground litter and deadwood disposed of. 10 feet of clearance around propane tanks.
Emergency accessDriveways with 13 feet 6 inches vertical and 20 feet horizontal clearance for fire engines. Reflective address signs visible from both directions.

Oregon State University Extension, EM 9184

EM 9184, "Keeping Your Home and Property Safe from Wildfire", was written by Max Bennett, Stephen Fitzgerald, Alicia Christiansen and Kara Baylog. It was published in December 2017 and reviewed in 2023. The guide recommends defensible space between a home and its surroundings of 100 feet or more.

The guide's Zone 1 runs from the house out to 30 feet and is called Lean, Clean and Green. Its Zone 1A is a noncombustible area at least 5 feet wide around the base of the home, kept free of woodpiles, wood mulches and flammable shrubs such as juniper. Zone 2 runs from 30 feet out to at least 100 feet, and up to 200 feet on steeper slopes with thicker vegetation. Zone 3 runs from Zone 2 to the property line.

The Zone 1 tasks include pruning mature trees to at least 10 feet and mowing grass to 4 inches. Zone 2 tasks include thinning dense patches of trees and shrubs so the groups are separated. A clump kept as a visual screen gets 5 to 10 feet cleared around it. For driveways the guide gives at least 13.5 feet of vertical clearance, with brush trimmed back 10 feet or more from the edge.

The guide treats maintenance as a recurring job. Zone 1 is maintained annually, and Zone 2 thinning and pruning happens every few years or on a portion each year so the whole area is treated within 5 to 8 years. Without maintenance, the guide says, the benefits of defensible space are lost in 5 to 10 years.

The two Oregon sources differ on some figures. The Fire Marshal's page lists tree pruning up 6 feet and 20 feet of horizontal driveway clearance. EM 9184 gives 10 feet of pruning height for mature trees and 10 feet of horizontal clearance from the driveway edge.

NFPA 1144, 2018 edition

The NSAI listing of NFPA 1144 gives the 2018 edition of "Reducing Structure Ignition Hazards from Wildland Fire", published by the National Fire Protection Association. It supersedes the 2013 edition and NFPA 299 (1997).

The abstract describes a method for assessing wildland fire ignition hazards around existing structures, residential developments and subdivisions, and improved or planned property in a wildland/urban interface area. It adds minimum requirements for new construction to reduce the chance of structure ignition from wildland fires. The contents run from administration and definitions through assessing hazards in the structure ignition zone, building design, location and construction, and fuel modification area.

Sources