Defensible space and trees: what CFA Victoria and the NFPA Firewise fact sheet publish

Victoria's standard planning permit conditions set tree canopy gaps of 5 metres and a 2 metre branch clearance. The Firewise fact sheet puts the key zone at 0 to 5 feet around a building.

Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.

This page reports what the official source says. It is not legal advice: ask the office named here. The Victorian text is a set of standard planning permit conditions. The US text is a Firewise wildfire research fact sheet.

Victoria: standard defendable space conditions

CFA publishes standard planning permit conditions for defendable space, updated May 2026. They sit at Table 4 of Clause 53.02-5 of the planning scheme, and CFA's note says they must not be altered unless CFA agrees in writing. The distance is left as XX metres in the template. The condition runs around the proposed building or to the property boundary, whichever is the lesser distance.

The conditions name these tree and plant limits inside that distance:

  • Trees must not overhang or touch any element of the building.
  • The canopy of trees must be separated by at least 5 metres.
  • There must be a clearance of at least 2 metres between the lowest tree branches and ground level.
  • Shrubs must not be located under the canopy of trees.
  • Individual shrubs and clumps of shrubs must not exceed 5 square metres in area and must be separated by at least 5 metres.
  • Plants taller than 10 centimetres must not be placed within 3 metres of a window or glass feature of the building.

The same list covers grass and litter. Grass must be short cropped and maintained during the declared fire danger period, and leaves and vegetation debris must be removed at regular intervals during that period. Within 10 metres of a building, flammable objects must not be located close to the vulnerable parts of the building.

Victoria: the 10/30 and 10/50 exemptions

A CFA news item from October 5, 2016 describes the planning exemptions known as the 10/30 and 10/50 rules, in place since 2011. In most areas outside Melbourne a permit is not needed to remove trees within 10 m of a home, or understorey vegetation up to 30 m from it. The item says the 10/50 rule applies in most bushfire risk areas.

CFA lists exceptions, mainly for newer homes. Residents of homes built or approved after September 10, 2009 still need a permit to clear any vegetation. CFA also points residents to local councils for any local laws, and to an online tool on its website for checking whether clearing needs a permit.

Victorian distances as printed by CFA
ItemDistanceDocument
Gap between tree canopiesAt least 5 metresStandard permit conditions
Lowest branches to groundAt least 2 metresStandard permit conditions
Tree removal without a permitWithin 10 m of a homeCFA news item, 2016
Understorey clearing without a permitUp to 30 m of a home (10/30 rule)CFA news item, 2016

United States: the immediate zone in the Firewise fact sheet

The Firewise wildfire research fact sheet, hosted by the Texas A&M Forest Service and made with the USDA Forest Service, the Department of the Interior and the National Association of State Foresters, covers the first 5 feet around a building. It reports research from the Insurance Institute for Business and Home Safety (IBHS) that the first 0 to 5 feet, called the immediate or noncombustible zone, has the greatest impact on risk. IBHS and the National Fire Protection Association (NFPA) recommend keeping that zone well maintained and clear of combustible materials.

The sheet cites more than 180 tests at the IBHS Research Center in 2018 on fire behaviour and heating of buildings. Its observations on landscaping:

  • Mulch thickness, wind speed and the location of flame and building all affect whether mulch ignites and how fast fire reaches the building.
  • Burning mulch makes embers that can ignite nearby mulch.
  • With flames 5 feet away, a building's surface stays below ignition temperature. Corners, at 45 degrees to the wind, run hotter even with a 5-foot space.

Its recommendations include keeping corners clear of combustibles, hard surfaces or rock mulch, a well irrigated lawn and low-growing non-woody plants. It states that shrubs and trees are not recommended in the 5-foot zone. Work on the home ignition zone, it adds, should not stop at 5 feet but extend away from the building up to 100 feet or to the property line.

Two different kinds of text

The Victorian conditions are standard permit wording, with metric limits on canopy, branch height and shrub clumps. The Firewise sheet gives recommendations with a different geometry: a 5-foot zone with no trees or shrubs, then a larger area out to 100 feet. For the plans that state agencies publish, see the guide to wildfire plans and tree clearing.