Electrical contact deaths in tree work: CDC, HSE and arborist incident review figures
The CDC counted 174 electrocutions among 1,285 US tree care deaths from 1992 to 2007, 14 percent. A 2020 review found 135 fatal electrical contact incidents from 2001 to 2017. The two HSE pages give no death count.
Checked against the sources at the bottom of this page on October 15, 2026. Rules, fees and pay change: the source has the last word.
This page reports what the official source says. It is not legal advice: ask the office named here. It is not training and does not teach the work.
CDC: 1992 to 2007
The CDC's Morbidity and Mortality Weekly Report of April 2009 counted 1,285 worker deaths in tree care and maintenance in the United States between 1992 and 2007. Contact with electric current caused 14 percent of them, 174 deaths. Struck by or against an object caused 42 percent and falls to a lower level 34 percent. Power lines were the primary injury source in 79 deaths, 6 percent.
The report also reviewed 45 NIOSH fatality investigations from 1985 to 2007. Thirteen were electrocutions:
- five involved bodily contact with a power line;
- five involved equipment, a chainsaw or an aerial lift bucket, that gave the current a path;
- two involved a branch that fell onto a power line and then touched the worker;
- one involved a line downed in a hurricane that was wrongly taken to be de-energized.
The authors state three limits. Deaths are probably undercounted because the census narratives are inconsistent and sometimes vague. Death rates could not be worked out, because the number of tree care workers is unknown. The investigations are a small convenience sample and do not represent all tree care deaths.
Arboriculture and Urban Forestry review: 2001 to 2017
Ball, Vosberg and Walsh reviewed 865 fatal and 441 nonfatal US arborist incidents from OSHA, BLS and NIOSH sources. Their paper puts exposure to electric current first among the subcategories: 135 fatal incidents (15.6 percent of fatal incidents reviewed) and 18 nonfatal (4.1 percent). It calls electrocution one of the most common causes of death in arboricultural operations, about 16 percent of fatalities, and far less common in nonfatal incidents.
| Kind of contact | Fatal | Nonfatal |
|---|---|---|
| Indirect, through a conductive object | 106 (12.3 percent) | 13 (2.9 percent) |
| Direct, body touching a conductor | 29 (3.4 percent) | 5 (1.1 percent) |
Among the 106 indirect deaths, 58 involved climbers, 30 ground workers and 18 aerial device operators. A saw, usually a metal pole pruner, touching a primary conductor caused 31 fatal incidents. A cut branch or frond falling onto a climber who was also touching a conductor caused 23. Climbing lines, work-positioning lanyards and taglines provided the path in four fatal and three nonfatal incidents.
Voltage was identified in 46 of the 135 investigation summaries. Most deaths were on primary conductors between 5.1 kV and 15 kV, five came from indirect contact with 120 volt secondary conductors, and one involved a 138 kV transmission line. Twenty-four electrocutions happened during line clearing work. The authors also cite BLS counts of about 67 tree trimmer deaths a year, under SOC code 37-3013, from 2003 to 2016.
HSE in Great Britain
HSE's guidance note GS6, Avoiding danger from overhead power lines (fourth edition, 2013), opens by saying that every year people at work are killed or seriously injured when they touch live overhead lines. The note lists machinery, equipment such as ladders and scaffold tubes, and activities such as loading and lifting. A wire need not be touched, because electricity can arc across small gaps. Forestry and arboriculture are among the industries the advice covers. Work within 10 metres, measured on the ground horizontally from below the nearest wire, is work whose risks are to be managed.
HSE's tree work page on power lines says contact causes fatal or severe electric shock and burn injuries. Working near live overhead lines and underground cables is responsible for many incidents every year, and a number of them relate to tree work near live electrical equipment. HSE uses the same 10 metre distance for seeking advice from the line owner, usually the network operator. Neither HSE document gives a count of deaths.
BLS tables
The Bureau of Labor Statistics posts its fatal injury tables for 2023 and 2024. Table A-5 lists fatal injuries by occupation and by event or exposure, as a spreadsheet file. The index page does not name tree trimmers or electricity. Yearly counts for tree trimmers and pruners are in the official injury figures by country, and four agency reports on power line contact are in electrical contact investigations.
Sources
- CDC, MMWR 58(15), Work-Related Fatalities Associated with Tree Care Operations, United States, 1992 to 2007, April 24, 2009, read October 15, 2026
- Ball, Vosberg and Walsh, A Review of United States Arboricultural Operation Fatal and Nonfatal Incidents (2001 to 2017), Arboriculture and Urban Forestry 46(2):67-83, March 2020, read October 15, 2026
- HSE, Avoiding danger from overhead power lines, GS6 (fourth edition), 2013, read October 15, 2026
- HSE, Avoiding danger from overhead power lines, GS6 (fourth edition), full text PDF, 2013, read October 15, 2026
- HSE, Working near power lines and cables (tree work), read October 15, 2026
- US Bureau of Labor Statistics, Census of Fatal Occupational Injuries tables index, read October 15, 2026