Electrical contact in tree work: what OSHA and HSE list as the hazard and the controls

OSHA calls contact with electricity one of the leading causes of death for tree care workers. OSHA 3861, 29 CFR 1910.269(r) and the HSE pages GS6 and Working near power lines set out the hazard and the controls they name.

Checked against the sources at the bottom of this page on October 19, 2026. Rules, fees and pay change: the source has the last word.

The named codes and training bodies are described here as published. It is not training and does not teach the work.

The hazard as OSHA frames it

OSHA publication 3861, Electricity and Tree Care Work, opens by calling contact with electricity one of the leading causes of death for tree care workers. It is written for small business owners and front line supervisors who do regular tree trimming, meaning work that is not line-clearance tree trimming.

The leaflet gives three examples, each linked to a NIOSH FACE report. A pole saw touched an energised overhead line while the worker trimmed from a portable work platform. A branch that was cut did not fully detach and struck an energised line. A felled tree landed on an overhead line and brought the line down. In the last case, the investigation found the family-owned firm had no written safety and health policy.

OSHA splits the contact into direct and indirect. Direct contact is with an energised conductor such as a power line. Indirect contact is through a tree limb or tool touching the line. It adds that workers should not stand close to grounding elements, because the power can travel through the ground.

Controls in OSHA 3861

  • Train workers about the hazards in a language they understand.
  • Survey the area for hazards before work starts, and have an emergency plan.
  • Consider asking the utility to de-energise nearby lines.
  • Maintain at least 10 feet from overhead lines, and more than 10 feet where the voltage to ground is over 50 kV, citing 29 CFR 1910.333(c)(3)(i). Protective clothing is not to be relied on alone.
  • Assume every line is energised at all times, and anticipate where limbs might fall onto power sources.
  • Provide proper gloves and shoes, and rope free of moisture and contaminants that gives appropriate insulation where electrical hazards are present.
  • Provide fall protection for climbers.

The leaflet points employers hired to clear trees from power lines to 29 CFR 1910.268, 1910.269 and Subpart S of Part 1910.

Line-clearance trimming under 29 CFR 1910.269(r)

Paragraph (r) of 1910.269 sets requirements for line-clearance tree trimming. Its electrical hazards provision, (r)(1), does not apply to qualified employees. For others, it states the following.

Requirements in 1910.269(r)(1) and (r)(7)
ParagraphRequirement
(r)(1)(i)Before anyone climbs, enters or works around a tree, the nominal voltage of lines posing a hazard is determined
(r)(1)(ii)A second line-clearance tree trimmer is within normal voice communication when a trimmer approaches closer than 10 feet to a conductor energised above 750 volts, when branches are closer than the table distances, or when roping is needed
(r)(1)(iii)Trimmers keep the minimum approach distances in Tables R-5 to R-8
(r)(1)(iv)Branches touching energised conductors or inside those distances are removed only with insulating equipment
(r)(1)(v)Ladders, platforms and aerial devices stay outside the same distances
(r)(1)(vi)No line-clearance trimming when adverse weather makes the work hazardous; thunderstorms, high winds, snow and ice storms are presumed too hazardous
(r)(7)(vii)A rope that is wet, or contaminated enough to impair its insulating capacity, is not used near exposed energised lines
(r)(8)Each employee working above ground in a tree is tied in with a climbing rope and safety saddle, unless ascending

HSE guidance note GS6

GS6, Avoiding danger from overhead power lines, fourth edition, is aimed at people who plan or supervise work near live lines. HSE states that people are killed or seriously injured every year when they contact live overhead lines. An overhead wire does not need to be touched to cause serious injury or death, because electricity can jump, or arc, across small gaps.

HSE adds that lines are easy to miss when people are tired or rushing, in fog or dull light, at the edge of woodland where they blend in, or where lines run parallel or under other lines. It tells readers to assume a line is live until the owner confirms it is dead.

The law, as HSE reports it, allows work close to live lines only when there is no alternative and the risks are acceptable and can be controlled. HSE ranks the options. Remove the risk by not working near the wires. Ask the owner whether the line can be diverted or replaced with underground cable. Ask whether it can be switched off temporarily. Then control the risk through a site-specific assessment. GS6 puts the management trigger at 10 metres, measured at ground level horizontally from below the nearest wire.

HSE on working near power lines

HSE's page says contact with overhead lines causes fatal or severe electric shock and burn injuries, and can happen when a person or object is close enough for a flashover. It says a number of the many incidents each year relate to tree work. Where arboricultural, aerial or ground work is proposed within 10 m of overhead lines, it asks for a risk-based approach and specialist advice from the line owner, usually the Network Operator.

The page also counts work beyond 10 m that could breach the distance: falling trees, timber and debris, or MEWPs and cranes that could fall within 10 m if they collapsed. Underground cables are a separate hazard. HSE calls working dead, with the power turned off, the first choice. A decision to work live must be justified, documented and meet the criteria of regulation 14 of the Electricity at Work Regulations. Where published guidance conflicts on safety distances, the Network Operator's advice is the one to seek.