ArbNation Join free

Felling near roads, buildings and power lines: Britain, NSW, New Zealand and OSHA codes

Codes from Britain, New South Wales, New Zealand and OSHA cover exclusion zones, traffic control and power line distances. NSW prints 3.0 m for ordinary persons near lines up to 132,000 volts, and New Zealand prints 4 m and 6 m.

Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.

This page draws on codes and guidance from HSE, SafeWork NSW, WorkSafe New Zealand, the Arboricultural Association and OSHA. It is not training and does not teach the work. Power lines have their own guide.

A felling onto a public road: the HSE case

HSE's case summary on felling trees records a member of the public seriously injured when a 7 metre lime tree was felled into a public road. A trained arborist felled it, even though it stood within the pavement near a crossroads. The contracting company did not carry out and record a site-specific risk assessment and used only signs and traffic cones to keep people out of the felling zone.

The contractor was prosecuted under Section 3(1) of the Health and Safety at Work Act for not taking adequate precautions to protect the public. It pleaded guilty and was fined £3,500 with £2,723 towards costs. HSE's advice on the case is that the accident could have easily been prevented by an on-site risk assessment, that the tree should have been sectionally dismantled, and that barriers should have been in place.

Exclusion zones, drop zones and roads in the SafeWork NSW code

SafeWork NSW's Tree works code of practice commenced on 27 March 2026 and replaced the 1998 Amenity Tree Industry code. Under sections 54 and 55 of the WHS Regulation, a business must manage the risk of an object such as a branch falling on a person. If the risk cannot be eliminated, it must be minimised by adequate protection and a safe system of work, which may include an exclusion zone persons are prohibited from entering.

The code lists exclusion zones for pedestrian access and footpaths, vehicle access and public roads, and hazardous operations of plant. It defines an exclusion zone as a large area from which people who are not workers are excluded. Where houses or other structures that may contain people lie inside an exclusion zone, steps must be taken to control the associated risks.

A drop zone is the area designated for the tree to land, or for material to land after cutting. Its size is set by a risk assessment. The factors listed include the size of the work area and the length and shape of the material. Sloped or uneven ground is one, and so is deflection off branches, roots, structures or hard surfaces. Exclusion distances must also allow for unexpected movement of falling, flying or rolling material.

For work on or directly beside a public road, the code puts the duty on the business to have appropriate traffic control, done by appropriately licensed and competent workers. It lists a traffic control plan from a competent person, plans submitted to the controller of the road, signs and barriers that conform to AS 1742.3:2019, and barriers that direct traffic around the site. Work on public road reserves may need traffic management plans and local council approvals.

Roads and transport corridors in the WorkSafe NZ code

WorkSafe New Zealand's Approved Code of Practice for Safety and Health in Arboriculture, November 2012, covers machines operating next to or on roads and road verges. Appropriate road signage is used in line with the consent and requirements of the New Zealand Transport Agency or the roading authority.

For an operation that poses a risk to or is in a transport corridor such as a road, rail or footpath, the code says operations do not proceed until the corridor manager has been advised and any requirements met. Where a road, footpath or public access is closed or partly closed, the same precautions apply and the manager's conditions must be complied with. A separate line on public safety says that if any risk of injury to the public exists, the site is managed so the public is safe.

Power line distances in three documents

SafeWork NSW Tree works code, approach distances for work near overhead electric lines
Who and what voltageApproach distance
Ordinary persons, Table 5: up to and including 132,000 volts AC3.0 m
Ordinary persons: above 132,000 up to and including 330,000 volts AC6.0 m
Ordinary persons: above 330,000 volts AC8.0 m
Ordinary persons: up to 1,500 volts DC3.0 m
Trained persons with a safety observer, Table 6: insulated low voltage cables up to 1,000 volts0.5 m
Trained persons: uninsulated low voltage conductors up to 1,000 volts1.0 m
Trained persons: above 1,000 up to 33,000 volts1.2 m
Trained persons: above 33,000 up to 66,000 volts1.4 m
Trained persons: above 66,000 up to 132,000 volts1.8 m
Trained persons: above 132,000 up to 220,000 volts2.4 m
Trained persons: 330,000 volts3.7 m
Trained persons: 500,000 volts4.6 m
Trained persons: up to 1,500 volts DC1.0 m
New Zealand and United Kingdom codes
DocumentWording
WorkSafe NZ code, section 2.2.11, referring to Electrical Code of Practice 34Persons not closer than 4 metres to lines up to and including 110 kV without written consent and safety conditions from the line owner. Never closer than 6 metres to lines over 110 kV. Mobile plant not closer than 4 metres to any line without that consent.
Arboricultural Association, Tree Work at Height, edition 2, May 2020, section 3.4.7Aerial tree works within 10 m (United Kingdom specific) of power lines, measured between any part of the tree and the line, call for a risk-based approach and specialist advice from the line owner.

SafeWork NSW adds that an ordinary person should not climb a tree within 3 metres of electric lines or cut branches that might come within 3 metres. The code treats overhead lines as live unless the electricity supply authority provides written documentation, and notes that trees and branches can conduct electricity even in dry conditions. The no-go zone is the area closer than the Table 6 distances, where work needs the supply authority's written approval.

The Arboricultural Association code says the basic principle within 10 m is to work with the electricity switched off, a measured safety or exclusion zone, or both, set by and agreed with the line owner. It says the first choice should be lines de-energised, and any decision to work with lines energised must be justified and documented. For highways and public rights of way it lists prior consultation or consent where needed, such as highway closures, site-specific risk assessments paying attention to highway users, pedestrians and neighbouring properties, and work areas signed, guarded and where appropriate lit.

OSHA 1910.269 and line-clearance tree trimming

OSHA's 29 CFR 1910.269 covers line-clearance tree trimming done to clear space around electric power lines or equipment, on behalf of an organisation that operates or controls those lines. The whole section except paragraph (r)(1) applies when qualified employees do the work. Paragraphs (a)(2), (a)(3), (b), (c), (g), (k), (p) and (r) apply when line-clearance tree trimmers who are not qualified employees do it. Those trimmers are to be trained and competent in telling exposed live parts from other parts, determining nominal voltage, and the minimum approach distances for the voltages they face.

To correct or remove an entry, write to the address at the foot of this page.

Sources