ArbNation Join free

Foot and handled ascenders: the codes, ITCC rules and EN 567 / EN 12841 listings

The UK industry code and the New South Wales code define one device, the ascender, and do not split foot ascenders from handled ones. The ITCC rule book does name foot and knee ascenders. EN 567 and EN 12841 are the standards cited.

Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.

Ascenders are described below as the UK industry code, SafeWork NSW, the ITCC rule book, BSI and one journal paper publish them. It is not training and does not teach the work.

The definitions

The Industry Code of Practice for Arboriculture: Tree Work at Height, Edition 2, May 2020, defines an ascender as a mechanical device used to ascend a rope. It slides when advanced up the rope and grips when loaded in the opposite direction. SafeWork NSW defines an ascender more widely, as a knot or mechanical device used for ascending a rope and positioning the climber in the tree.

Neither code divides ascenders into foot ascenders and handled ascenders. The terms are not defined in either document.

What the codes ask of ascending devices

The UK code, in clause 3.10.6.3, calls ascending devices components that connect to the rope. They let the rope travel through during ascent and lock off when loaded, so the climber does not descend unintentionally. They must meet three tests:

  • Be compatible with the ropes used, in diameter and type.
  • Be easy to adjust when moving up and down the working or backup line.
  • Grip effectively on the lines used.

Section 4.6 of the NSW Tree works code, March 2026, treats ascenders, descenders and rope grabs together. They should suit the rope specification, with attention to the recommended rope diameter. They should be self-locking or used with a device that is. Faulty equipment is removed from service. When mechanical ascenders are used, a backup on the main climbing line should be considered in case the ascender fails.

Where foot and knee ascenders appear

The ITCC Rule Book valid until 1 July 2024 uses the terms. Rule 7.2.11 requires the competitor to attach and configure the ascent system completely, naming foot or knee ascenders, foot loops, chest harnesses and tethers. At changeover, rule 7.2.23 says foot ascenders must come off the ascent line. Ascenders may stay on the line above the competitor if detached from the competitor. The book also lists a mechanical ascender as one way to form a system backup on the same line as the primary system.

Standards named for ascenders

Standards cited for ascenders and rope grabs
StandardTitle as printedWhere it is cited
BS EN 567Mountaineering equipment. Rope clamps. Safety requirements and test methodsUK industry code, Part 6 list of work equipment standards
BS EN 12841Personal fall protection equipment. Rope access systems. Rope adjustment devicesUK industry code, Part 6 list. BSI lists the 2024 edition as published March 31, 2024, current and under review

BSI's page for EN 12841:2024 is a catalogue entry with descriptors such as performance testing, locking and locating devices and instructions for use. The scope clauses of both standards were not opened.

Ascenders as Type B rope grabs

A 2011 paper by Brian Kane in Arboriculture & Urban Forestry reports on toothed ascenders tested on arborist climbing ropes. It describes ascenders as usually classed as Type B rope grabs under the 2006 edition of EN 12841. Climbers use them in place of a Prusik loop when footlocking a doubled rope, and with the single rope technique. The paper cites EN 12841-2006 and BS 567-1997 as standards to which ascenders are made.

It adds that a Type B grab on a working line goes with a safety line carrying a Type A rope grab. The Type B test limits arrest distance to 2 m. Of 67 drop tests, 10 met that limit. Kane notes that makers set explicit limits on ascender use, such as the rope construction and diameter.

Sources