Fuel can rules: CARB spill-proof, EPA Subpart F and CPSC child-resistance
Three US rule sets shape a portable fuel can: California's spill-proof performance standards, EPA's evaporative emission rule at 40 CFR Part 59 Subpart F, and CPSC's child-resistance rule at 16 CFR Part 1460.
Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.
This page reports what the official source says. It is not legal advice: ask the office named here.
California Air Resources Board, spill-proof standards
The California Air Resources Board adopted its portable fuel container regulation on July 6, 2000, as Title 13 of the California Code of Regulations, sections 2467 to 2467.8. It applies to any person who sells, supplies, offers for sale or manufactures for sale in California a portable fuel container or spout. The order defines a portable fuel container as a reusable container of ten gallons or less that is designed or used mainly for receiving, transporting, storing and dispensing fuel.
From January 1, 2001, a spill-proof system must meet six performance standards. The order lists an automatic shut-off before the target tank overflows. Also listed are automatic closing and sealing when removed, and one opening for filling and pouring. The order sets a minimum flow rate and fill level, a permeation rate of no more than 0.4 grams per gallon per day, and a warranty of at least one year against defects.
The flow rate depends on the nominal capacity. The minimum is one-half gallon per minute up to 1.5 gallons, one gallon per minute above 1.5 and up to 2.5 gallons, and two gallons per minute above 2.5 gallons. Between 1.5 and 2.5 gallons the order also allows the half-gallon rate if the can displays "Low Flow Rate" in type of 34 point or larger.
The order exempts safety cans meeting the federal requirements it cites, containers of one quart or less, and some rapid refueling devices and outboard engine tanks. Cans manufactured before January 1, 2001 could be sold until January 1, 2002 if a date of manufacture was displayed. The order says compliance does not exempt a can from state fire codes or other safety regulations.
EPA, 40 CFR Part 59 Subpart F
EPA's final rule on evaporative emissions from new and in-use portable fuel containers was published on February 26, 2007 (72 FR 8533). Section 59.600 applies it to containers manufactured on or after January 1, 2009. Hydrocarbon emissions are capped at 0.3 grams per gallon per day, measured with the diurnal venting and permeation test procedures. Spouts, caps, gaskets and other parts supplied with the container count as part of it.
Section 59.611 also requires that a container be free of leaks upright, partly inverted and fully inverted, and be built to minimize spillage during refueling to the extent practical. The standards apply through a useful life of five years from the date of sale.
The rule prohibits features that disable or bypass the emission controls. A vent that the operator can open is allowed if it closes automatically, without operator involvement, and is in place during emission testing.
Section 59.605 excludes safety cans approved under 29 CFR 1926.150 through 1926.152, containers with a nominal capacity under 0.25 gallons or over 10.0 gallons, and containers made only to feed fuel to nonroad engines in operation. EPA describes safety cans as usually having flash-arresting screens, spring-closing lids and spout covers, and as approved by a nationally recognized testing laboratory such as Factory Mutual or Underwriters Laboratories.
In a July 24, 2025 letter to manufacturers (IACD-2025-06), EPA said its rules do not prohibit vents in portable fuel containers. The letter notes that only a small number of cans on the market include a separate vent, and that slow fuel flow is one of the most common consumer complaints. It also acknowledges that cans must meet CPSC child-safety standards.
CPSC, 16 CFR Part 1460
The Children's Gasoline Burn Prevention Act regulation was issued under Public Law 110-278. Section 1460.3 requires each portable gasoline container manufactured on or after December 22, 2022 for sale in the United States to meet the child-resistance requirements for closures in sections 2 through 7 of ASTM F2517-22e1. That edition of the ASTM standard, Standard Specification for Determination of Child Resistance of Portable Fuel Containers for Consumer Use, was approved June 1, 2022.
The three rule sets side by side
| Rule | Applies to | Figure or standard |
|---|---|---|
| 13 CCR 2467 to 2467.8, California Air Resources Board | Containers and spouts sold in California from January 1, 2001 | Permeation 0.4 g per gallon per day; flow rates by capacity |
| 40 CFR Part 59 Subpart F, EPA | Containers manufactured on or after January 1, 2009 | 0.3 g per gallon per day; five-year useful life |
| 16 CFR Part 1460, CPSC | Gasoline containers manufactured on or after December 22, 2022 | ASTM F2517-22e1 child-resistance |
Mixing ratios and ethanol have their own guide, and so do storage and carrying rules.
Sources
- California Air Resources Board, Final Regulation Order: Portable Fuel Containers and Spouts, adopted July 6, 2000, read October 16, 2026
- U.S. Environmental Protection Agency, letter IACD-2025-06 to manufacturers, Clarification on Vents in Portable Fuel Containers, July 24, 2025, read October 16, 2026
- Legal Information Institute, 40 CFR Part 59 Subpart F, Control of Evaporative Emissions From New and In-Use Portable Fuel Containers, read October 16, 2026
- Electronic Code of Federal Regulations, 40 CFR 59.611 and 59.605 (renderer), read October 16, 2026
- Legal Information Institute, 16 CFR Part 1460, Children's Gasoline Burn Prevention Act Regulation, read October 16, 2026
- Electronic Code of Federal Regulations, 16 CFR 1460.3 Requirements for child-resistance for closures on portable gasoline containers, read October 16, 2026