Isolating a chipper before a jam or the knives: OSHA, PUWER and SafeWork NSW

OSHA 1910.147 requires an energy control program before servicing, PUWER regulation 19 requires a means to isolate equipment from all energy, and SafeWork NSW says wood-chipper controls should be isolated and tagged out.

Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.

This page reports what the official source says. It is not legal advice: ask the office named here. It is not training and does not teach the work.

United States: 29 CFR 1910.147, control of hazardous energy

The standard covers servicing and maintenance of machines where unexpected energization, start-up or release of stored energy could injure employees. It does not cover construction and agriculture. It also leaves out installations under the exclusive control of electric utilities and oil and gas well drilling and servicing.

Normal production operations are outside it. Servicing during production is inside only when an employee has to remove or bypass a guard or other safety device, or has to place any part of the body into the point of operation or an associated danger zone. A note excepts minor tool changes and adjustments that are routine, repetitive and integral to the equipment's use, if other measures give effective protection.

Paragraph (c)(1) requires an energy control program of energy control procedures, employee training and periodic inspections. Before any employee services or maintains a machine where unexpected energizing could cause injury, the machine must be isolated from its energy source and rendered inoperative. Under (c)(2), a tagout system is used where an energy isolating device cannot be locked out. Where it can be locked out, lockout is used unless the employer shows that tagout gives full employee protection.

OSHA bulletin on wood chippers

OSHA Safety and Health Information Bulletin 04-16-2008 states that it is not a standard and creates no new legal obligations. Its background cites the OSHA Integrated Management Information System: 39 employees were killed in chipper accidents from 1996 to 2005. The vast majority, 78%, were caught in the chipper, and most of the rest were struck by something.

The bulletin describes chipper knives that usually turn between 1,000 and 2,000 revolutions per minute behind a housing with a removable hood. On servicing, it says lockout/tagout procedures under 1910.147 must be used before any servicing begins, to control hazardous energy related to start-up. It also cites the Logging Operations standard, 29 CFR 1910.266(h)(4), under which chipper access covers or doors must not be opened until the drum or disc has come to a complete stop. A chipper hood safety latch is listed as an interlock. It stops the chipper starting before the hood is locked and the hood opening before the disc or drum has stopped.

Among its recommended work practices, the bulletin lists proper locking pins to immobilise the disc cutting wheel when clearing a clogged chute or changing blades.

United Kingdom: PUWER regulation 19

Regulation 19 of the Provision and Use of Work Equipment Regulations 1998, in force since December 5, 1998, is headed Isolation from sources of energy. It has three paragraphs.

  1. Where appropriate, every employer must see that work equipment has suitable means to isolate it from all its sources of energy.
  2. Those means are not suitable unless they are clearly identifiable and readily accessible.
  3. The employer must take appropriate measures so that reconnecting any energy source does not expose anyone using the equipment to a risk to health or safety.

New South Wales: Woodchipper guide, maintenance

The SafeWork NSW page quotes clause 210(1)(d) of the Work Health and Safety Regulation 2017. The person with management or control of plant must see that operator's controls can be locked into the off position to disconnect all motive power. It also cites clause 213 on maintenance and inspection of plant.

SafeWork NSW notes that every wood-chipper needs access to the cutting disc or drum for maintenance, operation and cleaning. Opening the access hatch or cover can expose the operator to entanglement, cutting and ejected fragments or blades. Before access to the inside, the controls should be isolated and tagged out and/or the key removed, so the machine cannot start unintentionally. A mechanical means of stopping the disc or drum from rotating should be used during maintenance. Maintenance and repairs should be recorded for each machine.