ArbNation Join free

Pole saws and pruners near power lines: OSHA 3861, Energy Safe Victoria and HSE

OSHA 3861 prints a 10 foot distance from overhead lines. Energy Safe Victoria prints a 3 metre No Go Zone for private tree contractors and names pole saws among the equipment that could touch lines.

Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.

The named regulators are described here as published. It is not training and does not teach the work. The figures below belong to the sources that print them, and they differ.

OSHA 3861

OSHA publication 3861, Electricity and Tree Care Work: A Deadly Combination, opens by calling contact with electricity one of the leading causes of death for tree care workers. It is written for small business owners and front line supervisors who do regular tree trimming, not line clearance. One example it gives is a landscaper who touched an energized overhead line with a pole saw while working from a portable work platform. No co-worker or supervisor was on site.

The leaflet's list of safe work practices starts with distance. It puts the minimum at 10 feet from overhead lines, and more than 10 feet where the voltage to ground is over 50 kV, citing 29 CFR 1910.333(c)(3)(i). Workers should not rely solely on protective clothing against electrical hazards. The leaflet rules out direct contact with an energized conductor, and indirect contact such as a tree limb or tool touching a power line. Its alert list starts with the line that all lines are to be assumed energized at all times.

OSHA 3861 also lists preparation points. They are training in a language the workers understand, a survey of the area for hazards before work begins, an emergency plan, and insulated footwear. It suggests asking the utility to de-energize nearby lines. On gear, it says employers must provide proper gloves and shoes and, where electrical hazards are present, rope that is free of moisture and contaminants and gives appropriate insulation. Employers hired to clear trees from power lines must follow the applicable OSHA requirements, and the leaflet gives 29 CFR 1910.268, 1910.269 and Subpart S as examples.

Energy Safe Victoria

Energy Safe Victoria's brochure Don't put your life on the line, dated December 2023, is addressed to tree industry workers. It says trees and branches can conduct electricity. A cut branch that falls onto a powerline can cause a fault to earth and electrocution. That can happen whether the pole saw or chainsaw is worked from the ground or in a tree.

The brochure sorts vegetation workers into three groups: those working for a private company or person, for a local council, and for a Victorian electricity supply industry company. Each group has its own documents. For private work, Energy Safe recommends keeping the 3 m No Go Zone clearance from powerlines when climbing trees. As a minimum, private contractors must comply with regulations 614, 616, 617 and 618 of the Electricity Safety (General) Regulations 2019.

The brochure names the equipment workers should keep monitoring: EWPs, ladders, ropes, pole saws and power pruners. The position of powerlines can change a great deal with wind and temperature. Anyone who works near a distributor's powerlines is required to notify the distributor.

An Energy Safe Victoria investigation, June 2024

Energy Safe Victoria published a case in which a crew was pruning a cypress near powerlines for an electricity distribution business. A crew member working from an EWP was repositioning a petrol pole pruner with a hedger attachment. The attachment touched an uninsulated high voltage conductor. The crew member felt a tingle and dropped the hedger. No one was hurt, and Energy Safe says the contact could have caused serious or fatal injury.

The investigation found that the hazard assessment omitted the powered hand-held hedge trimmer. The platform operator had limited vegetation management experience and had not yet been confirmed as competent for powered hand-held equipment. Safe approach distances were not kept, and the safety observer did not communicate effectively with the operator. Energy Safe issued the operator a warning letter under regulations 616 and 618, and sent the observer a letter on the role.

HSE and the 200 volt line

HSE's list of dangerous occurrences under RIDDOR includes unintentional contact between plant or equipment and an overhead electric line. Paragraph 3 of Schedule 2 covers an uninsulated line above 200 volts, and close proximity that causes an electrical discharge. HSE's examples are a crane or vehicle touching a line and something carried or lifted touching one. HSE prints no distance on that page.

What each source prints
SourceFigureWho it is for
OSHA 3861At least 10 feet from overhead lines, more above 50 kV to groundSmall tree-trimming businesses in the United States
Energy Safe Victoria3 m No Go Zone recommended, with regulations 614, 616, 617 and 618 as the minimumPrivate tree contractors in Victoria, Australia
HSE, RIDDORLines above 200 volts, uninsulated, or any contact causing a dischargeEmployers in Great Britain who report dangerous occurrences

Sources