Respirator labels and fit tests: NIOSH N95, FFP classes, WorkSafeBC and HSE
An N95 label means the filter lets no more than 5 percent of test particles through. British Columbia requires a fit test before issue and at least once a year, and HSE gives FFP1, FFP2 and FFP3 protection factors of 4, 10 and 20.
Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.
This page reports what the official source says. It is not legal advice: ask the office named here. The sources are NIOSH in the United States, Part 8 of the British Columbia Occupational Health and Safety Regulation, and two HSE publications in Great Britain.
NIOSH approval and the N95 label
NIOSH calls the N95 the most common type of filtering facepiece respirator. An N95 must let no more than 5 percent of the test particles through. NIOSH tests at a particle size near the worst case, so an approved respirator should filter hazardous particles as expected in real use.
Approval means the respirator met NIOSH quality assurance and performance requirements. The label carries the manufacturer name, a part number, the filter series and efficiency level, a TC approval number and the word NIOSH in capital block letters. A respirator missing these elements, NIOSH states, cannot be relied on to give the same protection. The other labels on the NIOSH list are N99, N100, R95, R99, R100, P95, P99 and P100.
FFP classes in Great Britain
HSE guidance on fit testing, dated October 2025, names three classes of disposable half mask. It lists BS EN 149:2001 + A1:2009, filtering half masks to protect against particles, among the standards it recommends as references. HSE defines the assigned protection factor as the workplace level of protection the facepiece is expected to give, used when selecting adequate equipment.
| Class | Assigned protection factor |
|---|---|
| FFP1 | 4 |
| FFP2 | 10 |
| FFP3 | 20 |
British Columbia, Part 8 of the regulation
Section 8.32 requires the employer to provide an appropriate respirator when a worker is or might be exposed to an air contaminant above a limit set by ACGIH or by the Board. Section 8.33 requires the employer to select the respirator in consultation with the worker and the safety committee or representative, following CSA Standard CAN/CSA-Z94.4-18. Only a respirator meeting a standard acceptable to the Board may be used against airborne contaminants.
Table 8-1 sets protection factors that multiply an exposure limit to give the maximum use concentration. Non-powered air-purifying types are listed as follows.
| Respirator type | Protection factor |
|---|---|
| Half facepiece, non-powered | 10 |
| Full facepiece, non-powered | 50 |
Fit tests and the face seal
Under section 8.40, a respirator that needs an effective face seal must not be issued to a worker until a fit test shows the facepiece seals on that wearer. The test is required before initial use, at least once a year, when the facepiece brand, model or size changes, and when a change in the user's physical condition could affect fit. Other protective equipment that could interfere must be worn during the test.
Section 8.39 requires a worker to be clean shaven where the respirator seals with the face. Section 8.41 requires a positive or negative pressure user seal check before each use of such a respirator. The British Columbia text was amended effective April 1, 2026, in section 8.33.
HSE gives the same reason from the British side. A major cause of leaks is poor fit, and HSE notes that people's faces vary so much that one type or size is unlikely to fit everyone. HSE says each type of tight-fitting facepiece a worker wears should be fit tested. A competent person should do the test, and HSE supports the Fit2Fit accreditation scheme of the British Safety Industry Federation, which is not compulsory. HSE adds that stubble and beards make a good seal impossible, and that equipment not relying on a tight fit exists.
Wood dust and smoke are dealt with in the guide to wood dust and health, the guide to wildfire smoke in tree work and the guide to respirators for tree work.
Sources
- CDC NIOSH, NIOSH-Approved Respirators and N95 filtering facepiece respirators, read October 16, 2026
- WorkSafeBC, Occupational Health and Safety Regulation, Part 8, sections 8.32 to 8.41, read October 16, 2026
- HSE, Fit testing basics (respiratory protective equipment), read October 16, 2026
- HSE, Guidance on respiratory protective equipment (RPE) fit testing, INDG479, October 2025, read October 16, 2026