Air curtain burners: the EPA definition and wood waste rules in 40 CFR 60 CCCC
40 CFR 60.2245 defines an air curtain incinerator as a unit that projects a curtain of air across an open chamber or pit. One burning only wood waste, clean lumber or yard waste meets a short list of opacity, testing and reporting rules.
Checked against the sources at the bottom of this page on October 19, 2026. Rules, fees and pay change: the source has the last word.
This page reports what the official source says. It is not legal advice: ask the office named here. The federal rule calls the unit an air curtain incinerator. No state air agency permit rule for these units is among the sources here.
The definition in 40 CFR 60.2245
Section 60.2245(a) says an air curtain incinerator operates by forcefully projecting a curtain of air across an open chamber or open pit in which combustion occurs. It can be built above or below ground, with or without refractory walls and floor. The section separates these units from conventional combustion devices with enclosed fireboxes and controlled air technology, such as mass burn, modular and fluidized bed combustors.
Subpart CCCC sets standards of performance for commercial and industrial solid waste incineration units and for air curtain incinerators. It became effective on August 7, 2013.
The wood waste track
Under section 60.2245(b), an air curtain incinerator that burns only certain materials meets just section 60.2242 and the air curtain sections 60.2245 through 60.2260. The materials are 100 percent wood waste, 100 percent clean lumber, or 100 percent of a mixture of only wood waste, clean lumber and yard waste. The definition of a solid waste incineration unit also excludes air curtain incinerators that burn only wood wastes, yard wastes and clean lumber and comply with the opacity limits.
| Term | Definition as printed |
|---|---|
| Wood waste | Untreated wood and untreated wood products, including tree stumps (whole or chipped), trees, tree limbs (whole or chipped), bark, sawdust, chips, scraps, slabs, millings and shavings |
| Wood waste, exclusions | Grass, grass clippings, bushes, shrubs and clippings from them from maintaining yards or other lands; construction, renovation or demolition wastes; clean lumber |
| Clean lumber | Wood or wood products that have been cut or shaped, wet, air-dried or kiln-dried, but not painted, pigment-stained or pressure-treated with compounds such as chromate copper arsenate, pentachlorophenol and creosote |
Opacity limits, testing and records
Section 60.2250 sets two opacity limits for an air curtain incinerator. Within 60 days after it reaches the charge rate at which it will operate, and no later than 180 days after initial startup, opacity is 10 percent or less. During the first 30 minutes of operation, the startup period, the limit is 35 percent or less. Both are averages of three 1-hour blocks of ten 6-minute values.
Section 60.2255 uses Method 9 of appendix A of the part to determine compliance. It calls for an initial opacity test and annual tests no more than 12 calendar months after the previous one.
Section 60.2260 has the operator submit, before construction starts, a notification of intent to construct, the planned initial startup date and the types of materials to be burned. Opacity test results stay on site for at least 5 years in paper or electronic form. Initial results are submitted no later than 60 days after the test, and annual results within 12 months of the previous report.
EPA's rule history
EPA's page on commercial and industrial solid waste incineration units says section 129 of the Clean Air Act directs it to limit nine air pollutants from four categories of solid waste incineration units. It lists a rule history for the subpart, with the first standards promulgated on December 1, 2000 and revised standards on March 21, 2011.
EPA proposed on March 17, 2026 to consolidate air curtain incinerator requirements across four section 129 rules for units used solely for wood waste, yard waste and clean lumber. It also rescinded, on March 17, 2026, an interim final rule of August 26, 2025 on temporary-use incinerators and air curtain incinerators used in disaster recovery. Burning rules for brush and chips sit in the guide to tree waste and chip rules.
Sources
- US eCFR, 40 CFR part 60 subpart CCCC, Standards of Performance for Commercial and Industrial Solid Waste Incineration Units (current text), read October 19, 2026
- Cornell Legal Information Institute, 40 CFR 60.2245 What is an air curtain incinerator?, read October 19, 2026
- US EPA, Commercial and Industrial Solid Waste Incineration Units (CISWI): New Source Performance Standards and Emission Guidelines, read October 19, 2026