Anchor and rigging terms in ANSI Z133: what OSHA and Oregon OSHA quote
ANSI Z133 is a voluntary standard, and a 1982 OSHA letter says OSHA had not adopted it. Public OSHA letters and an Oregon OSHA memo quote it on climbing line size and on hoisting a worker by crane.
Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.
The named codes and training bodies are described here as published. It is not training and does not teach the work. What follows is only what OSHA and Oregon OSHA have put in public letters about Z133 and anchors.
Where Z133 sits next to OSHA rules
OSHA's tree care standards page lists ANSI Z133.1, Arboricultural Operations Safety, under national consensus standards. It calls them voluntary and not OSHA regulations. Meeting an ANSI standard does not mean meeting OSHA policy, though OSHA has adopted the requirements of some ANSI standards. The same list names ANSI A300 for tree care practices, A92.2 for aerial devices, Z359.1 for personal fall arrest systems and ASME B30.5 for mobile and locomotive truck cranes.
A 1982 OSHA letter to the National Arborist Association took the same line. OSHA had not adopted ANSI Z133.1, so its officers would not cite within the parameters of it. The letter pointed instead to the telecommunications standard, 1910.268(g), for tree trimming near electrical hazards.
Climbing line size, as OSHA quoted Z133-2017
OSHA's letter of October 3, 2023 deals with the climbing rope rule in 1910.269(r)(7)(i). That rule sets a minimum diameter of 12 mm (0.5 inch), a minimum breaking strength of 10.2 kilonewtons (2,300 pounds) and elasticity of not more than 7 percent for synthetic rope. The Utility Line Clearance Safety Partnership asked whether a 7/16-inch rope could count as a de minimis condition.
OSHA answered by reading Z133-2017, section 8.2.4. For moving rope systems, that section calls for a synthetic climbing line of at least half an inch (12.7 mm) with a breaking strength of 5,400 pounds. Maximum working elongation is 7 percent at a 540-pound load. The line must be marked by its maker as suitable for climbing. An exception lets a line of not less than 7/16 inch (11 mm) be used when the employer shows no safety hazard and the arborist has been instructed in the line.
| Item | OSHA rule 1910.269(r)(7)(i) | OSHA de minimis conditions |
|---|---|---|
| Minimum diameter | 12 mm (0.5 inch) | 11.1125 mm (7/16 inch) |
| Minimum breaking strength | 10.2 kN (2,300 pounds) | 5,000 pounds (24.02 kN) |
| Elongation | 7 percent or less (synthetic) | 7 percent or less at 540 pounds (2.402 kN) |
OSHA lists seven conditions for the de minimis position. They are the 7/16-inch minimum, synthetic fibre, the 5,000-pound strength, the 7 percent limit, the maker's mark for tree climbing, use under the maker's instructions and a trained worker. OSHA calls the finding fact specific for each case. It ties the policy to the current 1910.269 and Z133 and says a new Z133 edition may change it. A draft revision of Z133-2017 was out for public comment at the time.
Crane hoisting and anchors in Oregon OSHA's memo
Oregon OSHA's technical guidance TG 2025-01, issued June 5, 2025, quotes Z133-2017, section 5.7.11. The section lets a qualified arborist be hoisted into position by crane when tied in with a climbing line and saddle and secured to an anchor point on or above the crane hook or to the crane boom. The memo sets that against 29 CFR 1910.180(h)(3)(v), which bars hoisting, lowering, swinging or travelling while anyone is on the load or hook.
Oregon OSHA's answer is that reliance on Z133 is not a defence to a violation of that rule. The employer may still argue that compliance is infeasible or a greater hazard, and the employer carries the burden of proof. The memo lists the alternatives an inspector should weigh:
- Hand felling from the ground under OAR 437-002-0310(5).
- An aerial lift, with a separate crane for heavy limbs.
- Climbing, if the tree is not decayed or damaged enough to make that unsafe.
- A personnel platform meeting 29 CFR 1926.1431, which Oregon OSHA treats as a de minimis violation of 1910.180(h)(3)(v).
- A crane used only as a fixed anchor for a rope access system, when the tree worker holds exclusive control of the crane and the anchorage meets OAR 437-002-2027(4)(b).
The memo defines exclusive control as a method that stops any other person from raising or lowering the hook, block, line or boom, rotating the boom or moving the crane. It adds that a line or boom can lower by gravity with the controls moved even when the crane is powered off. It also bars crane movement while any worker is attached to the rope access system. Its conclusion is that no worker may be hoisted by crane without a personnel platform meeting 1926.1431, and only after the employer shows safer access is infeasible.
Sources
- OSHA, letter of interpretation on climbing ropes under 1910.269(r)(7)(i), October 3, 2023, read October 16, 2026
- OSHA, Tree Care Industry: Standards (national consensus standards list), read October 16, 2026
- OSHA, letter to the National Arborist Association on ANSI Z133.1, November 15, 1982, read October 16, 2026
- Oregon OSHA, Technical Guidance TG 2025-01 on ANSI Z133-2017, June 5, 2025, read October 16, 2026