Climbing gear recall notice: Petzl ASTRO BOD FAST, ASTRO SIT FAST and CANYON GUIDE harnesses
Petzl ASTRO and CANYON GUIDE harnesses were recalled in May 2026 over a D-ring pin that can release. An inspection call in October 2023 came first. The sources are the CPSC, Health Canada, the UK product safety list and the maker.
Checked against the sources at the bottom of this page on October 9, 2026. Rules, fees and pay change: the source has the last word.
The Petzl ASTRO BOD FAST, ASTRO SIT FAST and CANYON GUIDE harnesses are covered by four records. These are the CPSC recall record and the Health Canada notice of May 14, 2026, the maker's archived inspection call of October 2023, and the UK product safety report of March 8, 2024. Other recalls are covered in the guide to climbing gear recalls and safety notices. The notices linked below are the record, and each is restated here in our own words.
The fault
The 2026 notices name a fault in the metal D-ring on the front of the harness: the pin that secures it can release, so the attachment point opens. The CPSC puts the result as a risk of serious injury or death from a fall. Health Canada calls it a fall hazard.
The earlier records describe the same part. The maker's October 25, 2023 inspection call found a defect on the gated opening attachment point of one ASTRO harness. A poor machining process of the metal D lets the pin slide completely sideways even with both screws in place. The risk is death by strangulation or by falling from height. The UK report of March 8, 2024 words it as a risk of injuries from unintentional opening of the attachment point, and gives no risk level.
Which harnesses
The CPSC and Health Canada list the same model numbers. The serial number is on a plastic label inside the waist belt, and the range for every model is lower than 23J 9999999 999.
| Product as the notice names it | Model numbers |
|---|---|
| ASTRO BOD FAST, European version | C083AA00, C083AA01, C083AA02 |
| ASTRO BOD FAST, International version | C083BA00, C083BA01, C083BA02, C083BA03, C083BA04, C083BA05 |
| ASTRO SIT FAST | C085AA00, C085AA01, C085AA02 |
| CANYON GUIDE | C086BA00, C086BA01 |
The harnesses are black with a yellow accent, except models C083BA03, C083BA04 and C083BA05, which are black. The CPSC puts them as meant for operators and work-at-height professionals. In the 2023 inspection call, a green sticker inside the plasticized label means the harness had already been inspected under that call.
Numbers, dates and reports
United States
- Recall date: May 14, 2026.
- Units: "About 29,300 (In addition, about 4,900 were sold in Canada)".
- Sold: March 2018 for the ASTRO models and March 2020 for the CANYON GUIDE, through October 2023.
- Reports: none.
- Place of origin: Romania and Malaysia.
Canada
- Original publication: May 14, 2026, as a joint recall with the CPSC.
- Units: 4,906 sold in Canada and 29,300 in the United States.
- Reports: none in Canada or the United States as of April 21, 2026.
United Kingdom
- Product safety report 2402-0115, published March 8, 2024, from the Office for Product Safety and Standards.
- Corrective action: the maker's safety alert requesting inspection. The same model numbers are listed, with serial numbers up to 23J 0000000 000 included.
Remedy and history
The 2026 CPSC record gives a free replacement D-ring kit, and Health Canada gives a free replacement kit with installation instructions. The CPSC lists the remedy type as repair. The 2023 inspection call asked owners to stop using the harnesses and run a pin test described on the maker's page. Its December 31, 2023 update reports that customers had inspected thousands of harnesses and the maker had inspected its own stock and production line. None showed the defect except the one that started the call.
The maker's archived page is the Petzl call for inspection of October 2023.
To correct or remove an entry, write to the address at the foot of this page.
Sources
- U.S. Consumer Product Safety Commission, recall record 26488 from the recalls web service, read October 9, 2026
- Health Canada, consumer product recall for Petzl ASTRO and CANYON GUIDE harnesses, read October 9, 2026
- Petzl, archived call for inspection of the ASTRO and CANYON GUIDE harnesses, read October 9, 2026
- Office for Product Safety and Standards, GOV.UK product safety report 2402-0115, read October 9, 2026