ArbNation Join free

Building distances to mature trees in US city codes: Portland, Albany and Seattle

Portland, Albany and Seattle all size the protected zone around a tree from one foot of radius per inch of trunk diameter. They differ on where the diameter is measured, what may enter the zone and who decides.

Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.

This page reports what the official source says. It is not legal advice: ask the office named here. The three texts are Portland City Code 11.60.030 and Chapter 11.50, Albany Ordinance 6041 amending Albany Municipal Code 7.98, and Seattle Department of Construction and Inspections (SDCI) Director's Rule 11-2023. No state code distance turned up in the sources. Other cities have their own pages, such as Portland and Seattle.

The three distance rules

Protected zone around a tree, by city text
City and textZone and how it is sizedEntry into the zone
Portland, code 11.60.030Root protection zone: a minimum one foot radius, measured horizontally from the face of the trunk, for each inch of tree diameterNew encroachments must total under 25 percent of the remaining zone and sit no closer than half the required radius
Albany, Ordinance 6041, AMC 7.98.020Critical root zone: a circle around the trunk centre, radius one foot per inch of trunk diameter plus the trunk radiusThe ordinance counts equipment, stored materials and unapproved excavation or fill as ways of removing a tree
Seattle, Director's Rule 11-2023Basic tree protection area: radius of one foot per inch of diameter at standard height, which is 4.5 feet above groundThe Director may approve excavation and construction inside the area, and the rule names the parts of the circle where it is allowed

Portland

Portland City Code 11.60.030 sets the root protection zone for trees on a development site. For street trees the City Administrator may prescribe more or less protection. Existing structures, paved surfaces and utilities inside the zone may stay. Chain link fencing at least six feet high, on eight-foot metal posts, marks the edge of the zone, and signs on the fence state the penalties for violations.

Inside the zone the code prohibits ground disturbance, vehicle or equipment access (except on existing streets or driveways), storage of equipment or materials, stockpiling, proposed buildings, impervious surfaces, underground utilities, excavation, fill and trenching. Landscaping required by Title 33 is allowed and is not an encroachment. An arborist can propose an alternative zone under the performance path, with a signed plan.

Section 11.50.040 sets when the preservation standards apply. On sites, they apply inside the root protection zone of a private tree 12 or more inches in diameter or a City tree six or more inches. The trigger is any ground disturbance, or a construction staging area over 100 square feet on unpaved ground. In streets, they apply to ground disturbance or staging not limited to paved surfaces where there is a street tree three or more inches in diameter.

Albany

Ordinance 6041 adds a definition to AMC 7.98.020. Its worked example is a tree with a circumference of 6.5 feet, a trunk radius of 1 foot and a diameter of 25 inches. The critical root zone is a circle of radius 26 feet, or 52 feet across. Trunk measurements follow the code's tree circumference, taken 4.5 feet above the mean ground level. The ordinance title says it amends the code to increase the number of protected trees and to prohibit activities that could harm them.

Seattle

Director's Rule 11-2023 says the diameter at standard height is measured at 4.5 feet, at the narrowest point below that where the trunk swells or tapers, and on the upper side of a slope. A tree that splits low has a diameter equal to the square root of the sum of each stem's diameter squared. The rule calls both the drip line method and the trunk diameter method, which multiplies the diameter by a factor of 6 to 18, industry standards. It cites ANSI A300 Part 5 and its companion publication on managing trees during construction.

The tree protection area drawn on plans can never be larger than the basic area. Where the drip line is a circle, any part inside it left out of the protection area stays at least half the drip line radius from the tree. For an irregular drip line the distance is at least 10 feet from the trunk. Off-site trees with canopies or roots reaching the lot get the whole area inside the drip line. In Neighborhood Residential zones, a Tier 2 tree may be removed only if the basic area would leave a principal dwelling or accessory unit under 15 feet wide.

Sources