ArbNation Join free

Fall factor, slack and swing falls: the 600 mm, 500 mm and 0.5 m limits

The NSW code limits a fall to 600 mm, the ICoP to 500 mm and the New Zealand code sets 0.5 m of slack. None of them uses the term fall factor. A 2011 drop-test paper defines it as fall distance over rope length.

Checked against the sources at the bottom of this page on October 19, 2026. Rules, fees and pay change: the source has the last word.

The named codes and training bodies are described here as published. It is not training and does not teach the work.

Credits: SafeWork NSW text is adapted from the Tree works code of practice (March 2026), copyright State of New South Wales (SafeWork NSW), licensed under Creative Commons Attribution 4.0; changes were made, because the text is summarised and reworded. WorkSafe New Zealand material is summarised from its Approved Code of Practice for Safety and Health in Arboriculture (November 2012), with the source acknowledged.

Limits on distance, slack and swing

SourceWording
SafeWork NSW code, 4.4 and 4.9 (Australia)A work positioning harness is not used where there is a risk of a free fall greater than 600 mm. Where a climbing rope is part of fall prevention, it is kept taut to limit the fall distance to 600 mm or less. A second attachment point is listed for work where an uncontrolled swing is a risk.
WorkSafe NZ code, 3.2.2 (New Zealand)There shall be no more than 0.5 metres of slack in the climbing line at any time. Supplementary anchor points shall be used where a fall or swing that may cause injury is possible.
ICoP, 3.8.6.3 (United Kingdom)The operator's primary system should not allow a potential fall distance exceeding 500 mm. A backup limits the distance and consequences of a fall if the primary system fails.
ICoP, 3.10.6.10 (United Kingdom)An adjustable lanyard is preferred because it can minimise slack and so reduce the distance and consequences of a fall.
WorkSafeBC Part 26, 26.12.0.4 (British Columbia)The tree-climbing system is positioned to minimise the risk of falling and colliding with an object while swinging on a climbing line in a pendulum-like motion.

The figures differ in kind. The NSW and ICoP numbers are fall distances. The New Zealand number is slack in the line, not a fall distance.

Fall factor in the research

Kane's 2011 paper in Arboriculture and Urban Forestry defines fall factor as the ratio of fall distance to the length of rope in the system. The NSW, New Zealand, ICoP and WorkSafeBC texts do not use the term.

The paper drop-tested toothed ascenders on four arborist climbing ropes. The drop mass was 86 kg. With 1000 mm of rope between the dynamometer and the ascender, the test represented a fall factor of 1.04. With 2000 mm it was 0.52, and a limited set of tests at 4000 mm gave 0.26.

Kane followed the EN 12841-2006 test for Type B rope grabs, with some changes. Of 67 tests, the arrest distance met the standard's limit of 2 m only 10 times. With 1000 mm of rope it did so three times in 33 tests, and with 2000 mm seven times in 34.

Impact loads averaged more than 5 kN. Adding a backup friction hitch above the ascender raised the load to more than 6 kN. Kane calls the drop test a worst-case scenario, and the paper's subject is toothed ascenders.

The standard behind the test

EN 12841 covers rope adjustment devices for rope access systems. The Estonian standards centre lists EVS-EN 12841:2024 as valid from March 1, 2024, in the series that includes EVS-EN 12841:2006. BSI lists BS EN 12841:2024 as published March 31, 2024, identical to the European standard, with a status of current and under review.

Both pages are catalogue entries. They give the scope and the dates but not the drop-test conditions, so the 2024 test is not described here.

Swing in the codes

The NSW code lists a second attachment point, a climbing lanyard or a second rope system, where there is a risk of an uncontrolled swing. It also asks whether an anchor will keep the worker from swinging toward conductors or other hazards. The New Zealand code asks for supplementary anchor points where a swing may cause injury. WorkSafeBC states the pendulum case in its own words.

Sources