Rope elongation and EN 1891 types A and B: test masses and the figures two makers declare
EN 1891 sets two types of low stretch rope: type A tested with 100 kg and type B with 80 kg. Two makers print the 5 percent limit at 150 kg and each rope's declared elongation.
Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.
This page draws on the named standards bodies and makers. It is not training and does not teach the work.
EN 1891 in the catalogue
BSI lists BS EN 1891:1998, Personal protective equipment for the prevention of falls from a height. Low stretch kernmantel ropes, as published on 15 September 1998. Its status is "Current, Under Review". The UIAA index lists a Low Stretch Ropes standard as UIAA 107 and a Static Ropes standard as UIAA 110, marked Coming Soon.
Types A and B in the maker papers
Singing Rock's technical parameters sheet for 2020 describes type A as a low stretch kernmantel rope for general use by persons in rope access, including all kinds of work positioning and restraint, rescue and caving. Type B is a low stretch kernmantel rope of lower performance, requiring greater care in use.
| Item | Type A | Type B |
|---|---|---|
| Static strength | 22 kN | 18 kN |
| Test mass in the fall test | 100 kg | 80 kg |
| Elongation limit | Not higher than 5 percent, loaded for 3 minutes with 150 kg after a 50 kg pretension | |
| Fall test | A 2 m rope tied off with figure-eight knots, fall factor 1 | |
Teufelberger's norms and standards brief gives the same two classes, and adds figures for knotted rope. It puts the EN 1891 diameter at 8.5 mm to 16 mm, and requires a melting point above 195 degrees C, which rules out polyethylene and polypropylene.
| Type | Strength, no knots | Strength, knotted | Falls |
|---|---|---|---|
| A | 22 kN | 15 kN | At least 5 with 100 kg |
| B | 18 kN | 12 kN | At least 5 with 80 kg |
Declared elongation by rope
Singing Rock lists static elongation for each rope in its static range. The figures are the maker's own declared values from its 2020 sheet.
| Rope and type | kN | Elongation % | Falls |
|---|---|---|---|
| STATIC R44 10,5 (A) | 31.5 | 3.4 | over 15 |
| STATIC R44 11 (A) | 34.9 | 3.2 | over 20 |
| STATIC 9 (B) | 24.4 | 3.3 | over 15 |
| STATIC 10,5 (A) | 30.4 | 3.3 | over 10 |
| STATIC 11 (A) | 34.5 | 3.3 | over 20 |
| CONTRA 10.5 (A) | 30 | 2 | over 20 |
The kN column is the rope's strength and the elongation column is static elongation, both declared by the maker.
Dynamic ropes under EN 892
Teufelberger lists three types of dynamic rope under EN 892. Each has a first-fall dynamic elongation limit of 40 percent.
| Type | Diameter, mm | Falls | Static elongation |
|---|---|---|---|
| Single | 8.9 to 11 | At least 5 with 80 kg | No more than 10 percent on 80 kg |
| Half | 7.5 to 9 | At least 5 with 55 kg, single strand | No more than 12 percent on 80 kg, single strand |
| Twin | 6.9 to 8 | At least 12 with 80 kg, as a pair | No more than 10 percent on 80 kg, as a pair |
The Singing Rock dynamic range declares its own figures per rope in the same sheet. A 9.3 mm single rope there shows static elongation of 7.5 percent, dynamic elongation of 34 percent, 5 falls and an impact force of 8.6 kN.
Climbing rope types and terminations have their own guide.
Sources
- BSI Knowledge, BS EN 1891:1998 Low stretch kernmantel ropes, read October 16, 2026
- UIAA, Safety Standards index page, read October 16, 2026
- Singing Rock, Technical parameters of ropes, 2020, read October 16, 2026
- Teufelberger, Norms and standards brief (file 25-08-24_norms-and-standards_en_brainbox.pdf), read October 16, 2026