Firewood energy equivalents: million Btu per cord in GJ and kWh
A cord of red oak holds 25.3 million Btu in the Missouri Department of Conservation table. That is 26.7 gigajoules or 7,415 kilowatt-hours at the NIST factors.
Checked against the sources at the bottom of this page on October 21, 2026. Rules, fees and pay change: the source has the last word.
The Missouri Department of Conservation and University of Maryland Extension print firewood heat as million Btu per cord. Forest Research prints gigajoules and kilowatt-hours for UK fuels. The gigajoule and kilowatt-hour figures for the US species are arithmetic done with the NIST conversion factors.
The factors used
| Unit | Equals | Use here |
|---|---|---|
| 1 Btu (International Table) | 1,055.056 joules | 1 million Btu is 1.055056 GJ |
| 1 kilowatt-hour | 3.6 megajoules, exact | 1 million Btu is 293.07 kWh |
| 1 cubic foot | 0.02831685 cubic metres | 1 cord is 3.6246 m³ |
| 1 short ton | 907.1847 kilograms | Pellet tons |
The Missouri Department of Conservation defines the standard cord as 128 cubic feet. It may be 4 by 4 by 8 feet or any other shape that multiplies out to 128 cubic feet. A face cord is 4 by 8 feet, with pieces anywhere between 14 and 24 inches long. The length of the wood determines how much fuel the face cord holds.
Species per cord
| Species | Million Btu | GJ and kWh |
|---|---|---|
| Osage orange | 30.7 | 32.4 GJ, 8,997 kWh |
| Hickory | 29.1 | 30.7 GJ, 8,528 kWh |
| Black locust | 28.1 | 29.6 GJ, 8,235 kWh |
| White oak | 27.0 | 28.5 GJ, 7,913 kWh |
| Red oak | 25.3 | 26.7 GJ, 7,415 kWh |
| Ash | 23.6 | 24.9 GJ, 6,916 kWh |
| Walnut | 21.8 | 23.0 GJ, 6,389 kWh |
| Elm | 21.4 | 22.6 GJ, 6,272 kWh |
| Sycamore | 20.7 | 21.8 GJ, 6,067 kWh |
| Shortleaf pine | 19.0 | 20.0 GJ, 5,568 kWh |
| Redcedar | 18.9 | 19.9 GJ, 5,539 kWh |
| Boxelder | 17.5 | 18.5 GJ, 5,129 kWh |
| Cottonwood | 16.1 | 17.0 GJ, 4,718 kWh |
The Missouri table lists Osage orange, hickory, black locust, white and red oak, ash, elm, shortleaf pine, redcedar, boxelder and cottonwood. The University of Maryland table adds walnut at 21.8 and sycamore at 20.7. It prints one entry for oak at 25.3 and one for white pine at 19.0. The oak figure matches Missouri's red oak, and the white pine figure matches its shortleaf pine, so the two sources agree where they overlap. Ash at 23.6 and elm at 21.4 are identical in both. Neither source prints the moisture content behind these figures.
Forest Research figures for UK fuels
Forest Research prints net calorific value, which excludes the heat recovered by condensing the water vapour from combustion. Its table is built on volume and mass rather than the cord. Its log guide names moisture content as the factor with the greatest effect on net calorific value, ahead of wood density.
| Fuel | Net CV by mass | Energy by volume |
|---|---|---|
| Log wood, stacked, air dry (20% moisture) | 14.7 GJ/tonne, 4.1 kWh/kg | 5,200 to 7,400 MJ/m³, 1,400 to 2,000 kWh/m³ at 350 to 500 kg/m³ |
| Wood chips (30% moisture) | 12.5 GJ/tonne, 3.5 kWh/kg | 3,100 MJ/m³, 870 kWh/m³ at 250 kg/m³ |
| Wood pellets (10% moisture) | 17 GJ/tonne, 4.8 kWh/kg | 11,000 MJ/m³, 3,100 kWh/m³ at 650 kg/m³ |
| Solid wood, oven dry | 19 GJ/tonne, 5.3 kWh/kg | 7,600 to 11,400 MJ/m³, 2,100 to 3,200 kWh/m³ at 400 to 600 kg/m³ |
A cord of 3.6246 cubic metres holds 18.8 to 26.8 GJ of air-dry log wood on the Forest Research volume range. That is 5,074 to 7,249 kWh. The US species figures from 16.1 to 30.7 million Btu span a wider band, since they cover species from cottonwood to Osage orange.
Pellets
The University of Maryland gives wood pellets about 8,250 Btu per pound and adds that all densified wood has the same Btu content whatever the species. Most pellets hold 5 to 10 percent moisture. Forest Research prints 17 GJ per tonne at 10 percent moisture, which is 15.4 GJ per short ton at the NIST factor.
What the sources leave open
The Btu per cord figures say nothing about moisture, split size or stacking gap. The Maryland sheet credits an outside woodburning chart for its table. The Forest Research page lists its heat values as typical. The cord figures are printed reference values for a full cord, not measured ones.
Sources
- University of Maryland Extension, Buying and Storing Firewood and Pellets, Fact Sheet FS-937, 2012, read October 21, 2026
- Missouri Department of Conservation, Home Heating, Missouri Conservationist, January 2007, read October 21, 2026
- Forest Research (UK), Typical calorific values of fuels, read October 21, 2026
- Forest Research (UK), Wood as Fuel: A Guide to Choosing and Drying Logs, read October 21, 2026
- US National Institute of Standards and Technology, Special Publication 811 Appendix B.8, factors for units listed by kind of quantity, read October 21, 2026