ArbNation Join free

Firewood energy equivalents: million Btu per cord in GJ and kWh

A cord of red oak holds 25.3 million Btu in the Missouri Department of Conservation table. That is 26.7 gigajoules or 7,415 kilowatt-hours at the NIST factors.

Checked against the sources at the bottom of this page on October 21, 2026. Rules, fees and pay change: the source has the last word.

The Missouri Department of Conservation and University of Maryland Extension print firewood heat as million Btu per cord. Forest Research prints gigajoules and kilowatt-hours for UK fuels. The gigajoule and kilowatt-hour figures for the US species are arithmetic done with the NIST conversion factors.

The factors used

Conversion factors from NIST Special Publication 811
UnitEqualsUse here
1 Btu (International Table)1,055.056 joules1 million Btu is 1.055056 GJ
1 kilowatt-hour3.6 megajoules, exact1 million Btu is 293.07 kWh
1 cubic foot0.02831685 cubic metres1 cord is 3.6246 m³
1 short ton907.1847 kilogramsPellet tons

The Missouri Department of Conservation defines the standard cord as 128 cubic feet. It may be 4 by 4 by 8 feet or any other shape that multiplies out to 128 cubic feet. A face cord is 4 by 8 feet, with pieces anywhere between 14 and 24 inches long. The length of the wood determines how much fuel the face cord holds.

Species per cord

Heat per full cord, as printed and converted
SpeciesMillion BtuGJ and kWh
Osage orange30.732.4 GJ, 8,997 kWh
Hickory29.130.7 GJ, 8,528 kWh
Black locust28.129.6 GJ, 8,235 kWh
White oak27.028.5 GJ, 7,913 kWh
Red oak25.326.7 GJ, 7,415 kWh
Ash23.624.9 GJ, 6,916 kWh
Walnut21.823.0 GJ, 6,389 kWh
Elm21.422.6 GJ, 6,272 kWh
Sycamore20.721.8 GJ, 6,067 kWh
Shortleaf pine19.020.0 GJ, 5,568 kWh
Redcedar18.919.9 GJ, 5,539 kWh
Boxelder17.518.5 GJ, 5,129 kWh
Cottonwood16.117.0 GJ, 4,718 kWh

The Missouri table lists Osage orange, hickory, black locust, white and red oak, ash, elm, shortleaf pine, redcedar, boxelder and cottonwood. The University of Maryland table adds walnut at 21.8 and sycamore at 20.7. It prints one entry for oak at 25.3 and one for white pine at 19.0. The oak figure matches Missouri's red oak, and the white pine figure matches its shortleaf pine, so the two sources agree where they overlap. Ash at 23.6 and elm at 21.4 are identical in both. Neither source prints the moisture content behind these figures.

Forest Research figures for UK fuels

Forest Research prints net calorific value, which excludes the heat recovered by condensing the water vapour from combustion. Its table is built on volume and mass rather than the cord. Its log guide names moisture content as the factor with the greatest effect on net calorific value, ahead of wood density.

Net calorific value and energy density, Forest Research
FuelNet CV by massEnergy by volume
Log wood, stacked, air dry (20% moisture)14.7 GJ/tonne, 4.1 kWh/kg5,200 to 7,400 MJ/m³, 1,400 to 2,000 kWh/m³ at 350 to 500 kg/m³
Wood chips (30% moisture)12.5 GJ/tonne, 3.5 kWh/kg3,100 MJ/m³, 870 kWh/m³ at 250 kg/m³
Wood pellets (10% moisture)17 GJ/tonne, 4.8 kWh/kg11,000 MJ/m³, 3,100 kWh/m³ at 650 kg/m³
Solid wood, oven dry19 GJ/tonne, 5.3 kWh/kg7,600 to 11,400 MJ/m³, 2,100 to 3,200 kWh/m³ at 400 to 600 kg/m³

A cord of 3.6246 cubic metres holds 18.8 to 26.8 GJ of air-dry log wood on the Forest Research volume range. That is 5,074 to 7,249 kWh. The US species figures from 16.1 to 30.7 million Btu span a wider band, since they cover species from cottonwood to Osage orange.

Pellets

The University of Maryland gives wood pellets about 8,250 Btu per pound and adds that all densified wood has the same Btu content whatever the species. Most pellets hold 5 to 10 percent moisture. Forest Research prints 17 GJ per tonne at 10 percent moisture, which is 15.4 GJ per short ton at the NIST factor.

What the sources leave open

The Btu per cord figures say nothing about moisture, split size or stacking gap. The Maryland sheet credits an outside woodburning chart for its table. The Forest Research page lists its heat values as typical. The cord figures are printed reference values for a full cord, not measured ones.

Sources