Ground protection and driveway weight: what Haringey, Fingal and BS 5837 publish

Councils set vehicle weight classes for crossovers and specify ground protection inside root protection areas. Haringey's light duty class stops at 3,500 kg. Fingal says ground protection for wheeled or tracked traffic should be designed by an engineer.

Checked against the sources at the bottom of this page on October 21, 2026. Rules, fees and pay change: the source has the last word.

This page reports what the official source says. It is not legal advice: ask the office named here. Three documents bear on surface damage from heavy vehicles: the BSI catalogue entry for BS 5837:2012, a London Borough of Haringey guidance note on vehicle crossovers, and a Fingal County Council landscape works specification.

BS 5837:2012 in the BSI catalogue

BSI lists BS 5837:2012, Trees in relation to design, demolition and construction. Recommendations, published April 30, 2012, with the status "Current, Under Review." It supersedes BS 5837:2005, which BSI marks as withdrawn.

BSI describes the standard as recommendations on tree care so that new construction or existing structures and their surrounding trees keep a sustainable relationship. It names arboriculturists, architects, builders, landscape architects, land managers, contractors and statutory undertakers as its audience. Its recommendations apply whether or not planning permission is required.

Haringey: crossover classes and weight

Haringey's vehicle crossover guidance notes cover the dropped kerb across a footway or verge, not the driveway inside the property. Under the Highways Act 1980, the council must have due regard to the need to prevent damage to a footway or verge, to allow safe access, and to keep traffic moving.

Haringey crossover types
TypeUse named in the notes
Light dutyLaden vehicles up to 3,500 kg. Temporary access for heavier vehicles needs a specific licence from the borough
Medium dutyResidential properties where up to two laden vehicles fit on the hardstanding
Heavy dutyLaden weight over 3,500 kg, and flats and commercial properties with access for several vehicles

The notes set the minimum clearance from footway level to the top of cables and pipes at 600 mm for a heavy duty crossover and 400 mm for a light duty one. Only contractors approved by the council can work on the public highway, under the New Roads and Street Works Act 1991.

Crossovers near a tree go to the council's Tree Section, which decides whether the tree is affected and whether it can be removed. If removal is refused, the crossover is not approved. The notes cite the NJUC Guidelines for works in proximity to trees: precautions must be taken when excavating within a distance from the tree equal to 4 times the circumference of the trunk. If a request is approved, the hard standing must be built before the crossover, so that the new crossover is not damaged during its construction.

Fingal: barriers and ground protection on housing sites

Fingal County Council's June 2008 specification for public open space in housing schemes cites BS 5837:2005, the edition BSI marks as withdrawn. It adds that retained trees should be protected by barriers, ground protection or both, installed before materials or machinery are brought onto the site and before demolition, development or soil stripping starts. Once erected, they should be regarded as sacrosanct and not removed or altered without prior approval of the Parks Division.

Where the tree protection plan shows that vehicles or pedestrians may enter the root protection area, the specification says the effects of construction activity should be addressed by a combination of barriers and ground protection. It sets out two cases.

  • Pedestrian movement: a single thickness of scaffold boards on a compressible layer over a geotextile, or supported by scaffold, may be acceptable (Figure 3 of the standard).
  • Wheeled or tracked traffic: the ground protection should be designed by an engineer for the likely loading. It may involve proprietary systems or reinforced concrete slabs (clauses 11.8 and 11.9 of the standard).

Access into the root protection area and the ground protection must be agreed in advance with the Parks Division. Barriers should be a scaffold framework in accordance with Figure 2 of BS 5837, with vertical tubes at most 3 m apart and weldmesh panels fixed with wire or scaffold clamps. Weldmesh panels on rubber or concrete feet are not resistant to impact and must not be used. Any transit of plant with booms, jibs and counterweights in close proximity to trees should be conducted under the supervision of a banksman. Concrete mixings, diesel oil and vehicle washings should not be discharged within 10 m of the tree stem.