Hydraulic injection and stored energy: what HSE and the NSW Resources Regulator publish about high-pressure oil
HSE says injection injury has been reported at over 100 bar and may occur as low as 7 bar. NSW recorded a hose failing at 350 bar. HSE's alert covers work on any hydraulic machinery.
Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.
The facts on this page come from the named regulators. It is not training and does not teach the work. The sources are an HSE safety alert (FOD 4-2014), an HSE page on high pressure fluid injection hazards, and a safety alert from the NSW Resources Regulator. None of them is written for tree work. They describe the hazard on piling rigs, farm machinery and mining equipment.
What injection injury is
The HSE alert describes hydraulic injection injury as the outer layer of skin broken by a jet of fluid under pressure. Serious reported cases have occurred at pressures over 100 bar (1,450 psi). The alert adds that anecdotal evidence points to injury at pressures as low as 7 bar (101.5 psi).
The alert says injection injury often follows the failure of a component in the mechanical system. The equipment then stays in use and pressurised while it leaks fluid. A person may meet the jet while using the equipment, or while inspecting or maintaining it after performance drops.
HSE names two ways the injury does harm: mechanical penetration of the surrounding and underlying tissue under pressure, and the toxicity of the injected fluid. Severity varies with pressure, proximity and jet size. Without medical treatment, after four to six hours the victim may feel intense throbbing pain that does not respond to pain medication, and untreated injuries can lead to amputation.
The HSE agriculture page says fluid injected under the skin can lead to injury that may need amputation or major surgery, and that even pinprick punctures in pipework can cause major injury.
Two incident reports
| Regulator and alert | What happened |
|---|---|
| HSE, FOD 4-2014, issued September 23, 2014 | A maintenance fitter died after a hand-powered grease gun was used to tension the track of a piling rig. The nipple joining the gun to the track mechanism detached and released grease under significant stored energy |
| NSW Resources Regulator, safety alert SA02-14, September 9, 2002 | A mineworker was injected with hydraulic oil when a supply hose at 350 bar (about 5,000 psi) broke away from a valve bank. He was sent to hospital and had several operations to remove the fluid |
The NSW investigation found the main hose connection was a threaded type while the other hoses on the bank were staple locked. The threaded fitting was damaged and had been replaced at least once since longwall operations began. Hoses were dragging on the ground, and nothing guarded the operator from failed hoses or connections.
What the regulators ask of employers and makers
HSE's alert asks anyone maintaining mechanical plant to inspect the integrity and security of grease nipples and pipe work adapters used in track tensioning, at routine service intervals and before tensioning at any time. Replacement fittings should match the original equipment manufacturer's specification, and HSE says verification of a replacement should be treated as a pressure test. It also asks that personnel know the steps if an injection injury occurs, particularly the need for immediate professional medical treatment.
The HSE agriculture page lists operator errors behind injection injuries:
- searching for leaks with bare hands;
- using incorrect pipe couplings and makeshift repairs;
- failing to replace damaged hoses;
- failing to release pressure during repair or maintenance.
Its design points include over-pressure protection, hose burst valves where component failure could injure someone, shut-off and drain valves, and components and pipework placed behind guards or away from people. Operator instructions are to cover how to remove pressure and carry out maintenance safely, keeping guards in position and the specifications for replacement parts. HSE points to standard BS EN 982, Safety requirements for fluid power systems and their components.
The NSW alert recommends five things for mines running high pressure hydraulics:
- a review of whether fittings suit the loads in all operating conditions;
- removal of the risk of damage to hydraulic components;
- guarding against high pressure discharge from failed hoses;
- a training review so all operators and maintenance staff know the danger;
- an emergency procedure for fluid injection.
It lists AS 2671 (fluid power and hydraulic systems), AS 2958.2 and AS 4024.1 for reference.
Lifting machines used in tree work are covered in the guide to cranes in tree work.
To correct or remove an entry, write to the address at the foot of this page.
Sources
- Health and Safety Executive (UK), Hydraulic injection injury, safety alert FOD 4-2014, issued September 23, 2014, read October 16, 2026
- Health and Safety Executive (UK), High pressure fluid injection hazards, agriculture machinery topic, read October 16, 2026
- NSW Resources Regulator, Safety alert SA02-14 Injury from high pressure fluid injection, created September 9, 2002, read October 16, 2026