Line-clearance tree work rules in California, Washington and Oregon against 1910.269

California, Washington and Oregon write their own line-clearance tree rules next to the federal OSHA standard 1910.269. They differ on voltage thresholds, who counts as qualified, and where the approach distances sit.

Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.

This page reports what the official source says. It is not legal advice: ask the office named here. It sets the federal standard, 29 CFR 1910.269(r), beside the state-plan rules of California (Title 8, Article 38), Washington (chapter 296-45 WAC) and Oregon (Division 2/RR of OAR chapter 437). Other state rules are listed in the guide to tree work rules by state and province.

The federal standard

Paragraph (a)(1)(i)(E) of 1910.269 covers line-clearance tree trimming done for the organization that operates the lines. Two groups are treated differently. When qualified employees do the work, the whole section applies except paragraph (r)(1). When line-clearance tree trimmers who are not qualified employees do it, paragraphs (a)(2), (a)(3), (b), (c), (g), (k), (p) and (r) apply.

The standard defines a line-clearance tree trimmer as an employee who, through related training or on-the-job experience or both, is familiar with the special techniques and hazards of the work. A qualified employee is one knowledgeable in the construction and operation of the power equipment involved and its hazards.

Paragraph (r)(1) is the electrical-hazard rule for trimmers who are not qualified employees:

  • Before anyone climbs, enters or works around a tree, the nominal voltage of the lines posing a hazard is determined, or the maximum voltage is assumed.
  • A second line-clearance tree trimmer within unassisted voice range is required in three cases. One is a trimmer approaching closer than 3.05 m (10 ft) to a conductor energized at more than 750 volts. Another is branches removed closer than the table distances to lines above 750 volts. The third is roping to remove branches from the conductors.
  • Trimmers keep the minimum approach distances in Tables R-5 to R-8. Branches touching or within those distances are removed only with insulating equipment.
  • Ladders, platforms and aerial devices stay outside the same distances.
  • No line-clearance tree trimming is done when adverse weather makes it hazardous. Thunderstorms, high winds, snow storms and ice storms are presumed too hazardous.

Table R-6 gives phase-to-ground distances for voltages up to 72.5 kV. They run from 0.63 m (2.07 ft) at 0.751 to 5.0 kV, to 0.77 m (2.53 ft) at 15.1 to 36.0 kV, and to 1.00 m (3.29 ft) at 46.1 to 72.5 kV. Above 900 m (3,000 ft), the distances are multiplied by a correction factor.

California

The Division of Occupational Safety and Health (Cal/OSHA) puts line-clearance tree trimming in Article 38 of the High-Voltage Electrical Safety Orders, sections 2950 and 2951. Section 2950 applies the article wherever a part of the worker's body, tools or equipment, or the tree parts being worked, is likely to come within the Table 1 distances. Table 1 applies to persons other than qualified line-clearance tree trimmers and trainees. It sets 10 ft (3.05 m) for nominal voltages from 0 to 50 kV, 10 ft 9 in at 50.1 to 72.5 kV, 12 ft 4 in at 72.6 to 121 kV and 35 ft at 785 to 800 kV.

Section 2950 has three exceptions. A qualified tree worker as defined in General Industry Safety Orders section 3420(b) may work within 10 ft, but no closer than 1 ft, of energized lines of 600 volts or less, when the provisions of section 3423 are met. Qualified telecommunication workers and qualified electrical workers may do restoration or emergency work if trained and experienced in line-clearance techniques.

Section 2700 defines a qualified line-clearance tree trimmer as a person who has completed a minimum of 18 months of related training and on-the-job experience. Section 2951 adds these duties:

  • A hazard inspection of the work location and a tailgate briefing before work begins.
  • Only qualified line-clearance tree trimmers, or trainees under their direct supervision, perform the operations.
  • Another qualified trimmer or trainee within unassisted voice range at each work location. A qualified high-voltage electrical worker may be the second person.
  • Branches contacting energized conductors are removed only with nonconductive equipment.
  • Work stops in thunderstorms, high winds, snow or ice, except emergency restoration. The note treats winds over 40 miles per hour, or 30 if material handling is involved, as high wind unless precautions are taken.

Washington

Washington's Department of Labor and Industries covers line-clearance tree-trimming in WAC 296-45-455. The text follows the federal paragraph, with one difference in number: the second-trimmer trigger is a conductor or apparatus energized at more than 600 volts, where the federal text says 750. The distances are in Table 2 of WAC 296-45-325. Its entries for 72.5 kV and below match the federal Table R-6 figures. Phase-to-ground, they are 2 ft 1 in at 0.751 to 5 kV, 2 ft 7 in at 15.1 to 36.0 kV and 3 ft 3 in at 46.1 to 72.5 kV.

WAC 296-45-455 also has a provision the federal paragraph lacks. A tree trimmer may climb out of a basket into a tree, or back, if tied in during the whole move and the employer can show it is the safest way.

The scope section, WAC 296-45-015, splits the work as the federal standard does. The chapter, except WAC 296-45-455, applies to qualified electrical employees. Sections 296-45-065, 067, 125, 135, 255, 315, 375 and 455 through 45530 apply to trimmers who are not qualified electrical employees. The definitions section adds a distance test. Line-clearance tree trimming is work on trees or brush within 3.05 m (10 ft) of supply lines at 50 kV to ground or less. For higher voltages it adds 0.10 m (4 in) for every 10 kV above 50. A trimmer is not a qualified electrical employee without the training in WAC 296-45-065.

Oregon

Oregon OSHA's rule 437-002-0300 states that 1910.269 is repealed in Oregon and that Division 2/RR applies instead. Rule 437-002-2300 covers line-clearance tree trimming in the same two-group structure as the federal standard. Rule 437-002-2317 follows the federal paragraph (r) with Oregon's own table names, RR-4 to RR-7, and a 600 volt trigger for the second trimmer.

Oregon also keeps a separate tree-service rule set. Rule 437-002-0301 says it does not apply to tree trimming operations within 10 feet of any high voltage (600 v) power lines or equipment, which Division 2/RR covers. Rule 437-002-0306 puts the distance for an unqualified person near lines at 10 ft up to 50 kV to ground, with 4 in added for each 10 kV above 50. It also says the power company is notified when work is within 10 ft of a line or a tree may fall within 10 ft of one.

Differences at a glance

PointWhat the rules print
Second trimmer triggerFederal: above 750 volts. Washington and Oregon: above 600 volts. California: a second qualified trimmer or trainee at each work location
Who may do the workCalifornia: qualified line-clearance tree trimmers and supervised trainees only. Federal, Washington and Oregon: trimmers and qualified employees, with separate duties
Qualified trimmerCalifornia: 18 months of training and experience. Federal and Washington: training or on-the-job experience, no set months
Distance tableFederal: Tables R-5 to R-8. Washington: Table 2 in 296-45-325. Oregon: RR-4 to RR-7. California: Table 1 in section 2950 for other persons
WeatherFederal, Washington, Oregon and California name thunderstorms, high winds, snow and ice. Only California prints wind speeds