ArbNation Join free

Noise exposure limits by country: action levels, limits and the duty each triggers

OSHA sets its hearing conservation action level at 85 dBA and its permissible level at 90 dBA. Great Britain uses 80, 85 and 87 dB. British Columbia has one limit of 85 dBA Lex.

Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.

This page reports what the official source says. It is not legal advice: ask the office named here. It covers the United States (OSHA 29 CFR 1910.95), Great Britain (Control of Noise at Work Regulations 2005) and British Columbia (OHS Regulation Part 7).

Levels side by side

Noise levels in the three rules
RuleLevelWhat it is called
OSHA 1910.9585 dBA, 8-hour average (or 50 percent dose)Action level
OSHA 1910.95, Table G-1690 dBA for 8 hours; 92 for 6; 95 for 4; 97 for 3; 100 for 2; 102 for 1.5Permissible noise exposure
Great Britain, lower80 dB(A) daily or weekly; peak 135 dB(C)Lower exposure action value
Great Britain, upper85 dB(A) daily or weekly; peak 137 dB(C)Upper exposure action value
Great Britain, limit87 dB(A) daily or weekly; peak 140 dB(C)Exposure limit value
British Columbia 7.285 dBA Lex daily; peak 140 dBCNoise exposure limits

Table G-16 continues to 105 dBA for 1 hour, 110 for half an hour and 115 for a quarter hour or less.

United States

OSHA 1910.95(c) requires a continuing hearing conservation program whenever employee exposures equal or exceed an 8-hour time-weighted average of 85 decibels on the A scale, slow response, or a dose of fifty percent. The standard calls that level the action level. At and above it the employer must also:

  • run a monitoring program when information shows exposure may reach 85, and notify exposed employees of the results;
  • make audiometric testing available, with a baseline audiogram within 6 months of first exposure at or above the action level and a new audiogram at least annually;
  • make hearing protectors available at no cost;
  • train each exposed employee.

Paragraph (b)(1) covers the 90 dBA row. When employees are subjected to sound exceeding Table G-16, feasible administrative or engineering controls must be used. If they fail to bring levels within the table, personal protective equipment must be provided and used. Under (j)(2) and (j)(3), hearing protectors must attenuate exposure at least to an 8-hour average of 90 decibels, and to 85 or below for employees who have experienced a standard threshold shift.

Great Britain

Regulation 4 sets the lower and upper action values and the limit value. HSE's page on the regulations states the duties. At 85 dB(A) daily or weekly average, employers must provide hearing protection and hearing protection zones. At 80 dB(A), they must assess the risk to workers' health and provide information and training. Above 87 dB(A), taking account of any reduction from hearing protection, workers must not be exposed.

Regulation 4(4) lets an employer use weekly exposure where noise varies markedly from day to day. Regulation 4(5) counts hearing protection against the limit value but not against the action values.

The same Regulations build on those numbers. Regulation 6(2) requires a programme of organisational and technical measures, excluding hearing protectors, where an employee is likely to be exposed at or above an upper action value. Regulation 7 has the employer make hearing protectors available on request at the lower value, and provide them where other means cannot bring noise below the upper value. It also requires a Hearing Protection Zone, marked with the safety sign, wherever exposure is likely at or above the upper value. HSE adds that the 2005 Regulations bring in health surveillance for workers regularly exposed above 85 dB(A).

British Columbia

Section 7.2 sets two limits: 85 dBA Lex daily noise exposure and 140 dBC peak sound level. Section 7.3 requires the employer to measure noise exposure when a worker is or may be exposed to potentially harmful levels of noise, or when information indicates a worker may be exposed above 82 dBA Lex. Measurement is performed in accordance with CSA Standard Z107.56-94.

Where noise exceeds either limit, section 7.5 requires a noise control and hearing conservation program with seven elements: measurement, education and training, engineered noise control, hearing protection, posting of noise hazard areas, hearing tests and an annual program review. Under section 7.8, workers exposed above the limits get an initial hearing test within 6 months of starting and a test at least every 12 months after that. Where levels cannot practicably be brought to or below the limits, section 7.7 requires hearing protection that meets CSA Standard Z94.2-02, and workers in a posted noise hazard area must wear it.

Sources