ArbNation Join free

OSHA 1910.265 sawmills: the sections in order

Standard 1910.265 is the federal general industry rule for sawmills. It runs from paragraph (a) to (f): scope, definitions, buildings and equipment, log handling, log breakdown machinery and dry kilns.

Checked against the sources at the bottom of this page on October 19, 2026. Rules, fees and pay change: the source has the last word.

This page reports what the official source says. It is not legal advice: ask the office named here. The standard is 29 CFR 1910.265, Sawmills, in Subpart R, Special Industries, of Part 1910, Occupational Safety and Health Standards. It was issued on June 27, 1974 and last amended on November 18, 2016. OSHA also publishes a Sawmills safety and health topic page. The standard has six lettered paragraphs, set out below in order.

Paragraph (a): application

The section covers sawmill operations including, but not limited to, log and lumber handling, sawing, trimming and planing, waste disposal, dry kilns, finishing, shipping, storage, yard and yard equipment, and the power tools used with them. It excludes the manufacture of plywood, cooperage and veneer.

Paragraph (b): definitions

Paragraph (b) defines the terms used in the section. The list includes A-frame, binder, boom, brow log, bunk, cant, carriage, carrier, chipper and chock. A brow log, for example, is a log placed parallel to a roadway at a landing or dump to protect vehicles while loading or unloading. A cant is a log slabbed on one or more sides.

Paragraph (c): building facilities and isolated equipment

Paragraph (c) is the longest. Its numbered subparagraphs run from (c)(1) to (c)(31), with several reserved.

Subparagraphs of 1910.265(c)
SubparagraphSubject and figures in the text
(c)(1) to (c)(3)Safety factor for buildings, docks, tramways, walkways and log dumps. Work areas under mills lit to American National Standard A11.1-1965. Floors of adequate strength, with openings fenced or marked, and floors that minimize slipping
(c)(4) and (c)(5)Walkways, docks and platforms. A standard railing on raised walks 4 feet or more above the floor, and a toe board above 6 feet. Stairway handrails: one side, both sides over 4 feet wide, a third in the centre over 8 feet wide
(c)(6) to (c)(9)Emergency exits and doors, ventilation, open vats and tanks, lighting
(c)(11), (c)(13), (c)(15)Hazard marking under 1910.144. Equipment held by hydraulic pressure blocked, chained or otherwise secured for maintenance. Gas piping to Z21.30-1964
(c)(18) and (c)(19)Conveyors to B20.1-1957, with spiked live rolls guarded. Tramways and trestles: 22 feet vertical clearance over railroad rails. Over carrier docks or roads, 6 feet above the driver's footrest on the carrier and never under 12 feet from the roadway
(c)(20)Blower, collecting and exhaust systems. A collecting system is required in mills with machines that make dust, shavings, chips or slivers for one-fourth of the working day or more
(c)(21)Chippers and hogs. Whole-log chipper spouts enclosed to at least 36 inches from the floor or platform. Hog mills with at least 40 inches from the chute rim to the cutter knives
(c)(23)Bins, bunkers, hoppers and fuel houses. Handrails and toe boards, or a grating, where upper edges are under 3 feet above working level
(c)(24)Ropes, cables, slings and chains, set out below
(c)(26) and (c)(27)Mechanical stackers and unstackers. Lumber piling and storage, with stickers the full width of the package, lapped at least 12 inches and protruding no more than 2 inches
(c)(28) and (c)(29)Lumber loading built and secured for stability in transit. Burner stacks and runways
(c)(30)Vehicles: audible warning signals, lights, overhead guards, brakes, load limits. Lumber hauling trucks need a bulkhead where a load shift would endanger the operator, and at least two locked rollers where rollers are used
(c)(31)Traffic control and flow: posted crossings, marked clearances, pickup points and aisle width

Ropes, cables, slings and chains: (c)(24)

Ropes, cables, slings and chains are to be used within the maker's recommended limits. Open hooks are barred in rigging where relieving tension or fouling creates a hazard. Installation, inspection, maintenance, repair and testing are work for qualified persons. Wire rope is inspected on installation and weekly in use. The text lists removal points:

  • Three broken wires in one lay of 6 by 6 rope.
  • Six in one lay of 6 by 19 rope.
  • Nine in one lay of 6 by 37 rope.
  • Eight in one lay of 8 by 19 rope.
  • Marked corrosion, or a kink.
  • For other types, 4 percent of the wires broken in one lay.

Chains in load-carrying service are inspected before first use and weekly after that. A chain is discarded if any 3-foot length has stretched one-third the length of a link. Bolts or nails between links are barred. Frozen fiber rope is barred from load-carrying service. Hoisting cable keeps at least two full wraps on the drum, and running lines within 6 feet 6 inches of the ground are guarded or the area is restricted.

Paragraph (d): log handling, sorting and storage

Paragraph (d)(1) covers unloading. Binders on logs are not released before the logs are secured with unloading lines or another device, and are released from the unloader's side unless remote release or racks protect the person. Hoisting machines carry brakes able to hold the maximum load in midair. Hydraulic log machines carry a positive device against uncontrolled lowering, and powered lift arms carry a limit switch. Mobile log handling machines carry headlights and backup lights. Wood pike poles are made of straight-grained select material, and metal or conductive pike poles are barred around exposed energised conductors.

Paragraph (d)(2) covers unloading and storage areas, water log dumps, log booms and ponds, pond boats and rafts, dry deck storage, and log hauls and slips. It requires signs against unauthorized traffic and lighting at night. At water log dumps, ungrounded electric hoists with handheld remote control operate on circuits under 50 volts to ground. Approved life rings with line are provided. Workers on boats, floating logs, boom sticks or walkways on water wear buoyant devices. Stiff booms are two float logs wide.

Paragraph (d)(3) covers log decks, with stops against logs rolling onto the carriage and a barricade between the sawyer's stand and the deck. Paragraph (d)(4) covers mechanical barkers, including guarding of rotary barkers and holddown rolls at ring barker infeed and outfeed.

Paragraph (e): log breakdown machinery

Paragraph (e) goes machine by machine, in the order logs pass through a mill:

  • (e)(1) Log carriages and runways: bumpers at both ends, a positive means to prevent unintended carriage movement, a barrier and warning signs around the carriage travel space, and dogs adequate to secure the log.
  • (e)(2) Head saws: band, single circular, twin circular and whole-log sash gang saws. Speeds stay within the maker's limit, and a bandsaw with a crack over one-tenth of its width is not placed in service. Band head saw wheels get monthly inspection, and wheels are encased except near the blade exit.
  • (e)(3) Resaws: band, circular gang and sash gang.
  • (e)(4) Trimmer saws: front baffles, end and rear guards, and safety stops against saws dropping on the table.
  • (e)(5) Edgers: guards, pressure feed rolls, and safety fingers or other antikickback devices.
  • (e)(6) Planers: guarded cutting heads, hoods and pressure feed rolls.

Paragraph (f): dry kilns and facilities

Paragraph (f) has eight items. Kilns stand on solid foundations. Passageways run on at least one side or the centre of end-piled kilns and on two sides of cross-piled kilns. Main doors have a hold-open method, and escape doors that open easily from inside are required where procedure calls for access to kilns. Pits are ventilated, drained and lit. High-pressure steam mains in or near a pit are insulated. Roof access is by fixed ladder or other means, with chocks or blocking for cars, and a warm room for kiln employees in cold weather.

What the section does not contain

The section has no noise paragraph. OSHA's Sawmills standards page points to state plan rules for sawmills in California and Washington, and states they are not OSHA regulations.

Sources