OSHA 1910.269 and line-clearance tree trimming: scope, rules and the 2015 memo

OSHA's standard 1910.269 reaches tree trimming within 10 feet of electric supply lines, but only for work done for the utility. The 2015 enforcement memo and the standard's own note draw that line.

Checked against the sources at the bottom of this page on October 15, 2026. Rules, fees and pay change: the source has the last word.

This page reports what the official source says. It is not legal advice: ask the office named here. The standard is 29 CFR 1910.269, Electric Power Generation, Transmission, and Distribution, on the OSHA website and in the eCFR. Two OSHA letters of interpretation explain how it applies to tree work.

Scope for tree trimming

Paragraph (a)(1)(i)(E) brings in line-clearance tree trimming performed to clear space around electric power generation, transmission or distribution lines or equipment, and on behalf of an organization that operates, or controls the operating procedures for, those lines or equipment. Both conditions apply. Paragraph (a)(1)(ii)(A) keeps this work in the standard even where it counts as construction.

The standard splits the work by who does it:

  • Qualified employees: the entire section applies, except paragraph (r)(1).
  • Line-clearance tree trimmers who are not qualified employees: paragraphs (a)(2), (a)(3), (b), (c), (g), (k), (p) and (r) apply.

A qualified employee has the training in paragraph (a)(2)(ii), which covers telling live parts from other parts, finding nominal voltage, minimum approach distances, and recognizing electrical hazards. The definitions add that a line-clearance tree trimmer is not a qualified employee without that training. Under the separate electrical work-practices rules in subpart S, a line-clearance tree trimmer is treated as qualified.

The 10-foot definition

The standard defines line-clearance tree trimming as pruning, trimming, repairing, maintaining, removing or clearing trees, or cutting brush, within set distances of electric supply lines and equipment. For voltages to ground of 50 kilovolts or less the distance is 3.05 metres (10 feet). Above 50 kilovolts it is 3.05 metres plus 0.10 metres (4 inches) for every 10 kilovolts over 50.

A note to the definition repeats the scope limits. Tree trimming for a homeowner or for a commercial entity that is not the operator of the lines is outside the section. So is trimming not aimed at clearing space around the lines. That work may fall under other standards, and the note names 1910.268 and 1910.331 through 1910.335.

What paragraph (r) sets

Paragraph (r) holds the extra rules for line-clearance tree trimming and its equipment. Its first part, (r)(1) on electrical hazards, does not apply to qualified employees. The main items are:

Line-clearance tree trimming provisions in 1910.269(r)
TopicWhat the standard says
VoltageA determination of the nominal voltage of the lines posing a hazard is made before an employee climbs, enters or works around any tree. The maximum voltage may be used if all lines are treated as energized at it.
Second trimmerA second line-clearance tree trimmer is within normal voice communication in three cases. A trimmer will come closer than 3.05 metres (10 feet) to a conductor or apparatus energized above 750 volts. Branches being removed are closer than the table distances. Roping is needed to remove branches from such conductors.
Approach distancesTrimmers keep the minimum approach distances in the standard's tables. Branches touching exposed energized conductors, or inside those distances, are removed only with insulating equipment. Ladders, platforms and aerial devices stay outside the same distances.
WeatherThe work is not performed when adverse weather makes it hazardous. Thunderstorms nearby, high winds, snow storms and ice storms are presumed to make it too hazardous. Storm and emergency work calls for training in the special hazards.
Climbing rope and saddleClimbing ropes have a minimum diameter of 12 millimetres (0.5 inch) and a minimum breaking strength of 10.2 kilonewtons (2,300 pounds). A rope is inspected before each use and may not be spliced to repair it. An employee working above ground in a tree is tied in with a climbing rope and safety saddle, unless ascending into the tree.
Power sawsA saw heavier than 6.8 kilograms (15 pounds) used in trees is supported by a separate line, with exceptions. A saw has an idling control and a clutch that does not engage the chain at idle, and a running saw is not carried up a tree.
Chippers and stump cuttersChippers need an ignition locking device and secure access panels. Stump cutters need enclosures or guards.

The February 18, 2015 memorandum

OSHA's Deputy Assistant Secretary and the Director of the Directorate of Enforcement Programs sent this memo to Regional Administrators. It states that 1910.269 covers only line-clearance tree trimming done to clear space around lines or equipment and on behalf of the organization that operates or controls them. Trimming for a homeowner or another commercial entity is not covered.

OSHA said it intended to issue a correcting amendment. Until then it would issue no citations under 1910.269 for trimming that did not meet both conditions. The memo adds that citations could still come under other standards, such as 1910.268 or 1910.331 through 1910.335. OSHA's page for the memo carries an archive notice: it may no longer represent OSHA policy. The text of the standard in the eCFR carries the same two limits in paragraph (a)(1)(i)(E) and in the note to the definition.

The October 29, 1998 letter on apparel

A utility safety specialist asked what apparel rules apply to trimmers who are not qualified, since paragraph (r) has none. OSHA's Directorate of Compliance Programs pointed to paragraph (g)(1): personal protective equipment, which may include clothing, meets subpart I and is provided, used and maintained as 1910.132 requires. It must suit the hazards found in the hazard assessment under 1910.132(d).