ArbNation Join free

Pole saws and pole pruners: ISO 11680, OSHA, HSE and a maker's manual on power lines

Pole saws sit under ISO 11680, which leaves electric shock from overhead lines to the maker's warnings. OSHA says 10 feet, HSE says 10 metres, and one battery pole saw manual says 50 feet.

Checked against the sources at the bottom of this page on October 19, 2026. Rules, fees and pay change: the source has the last word.

The named codes and training bodies are described here as published. It is not training and does not teach the work.

ISO 11680 and its scope

ISO 11680-1:2021 is titled Machinery for forestry: safety requirements and testing for pole-mounted powered pruners, Part 1, machines fitted with an integral combustion engine. The ISME standards catalogue entry gives the scope. It covers portable, hand-held, pole-mounted powered pruners, extendable and telescopic ones included. A power transmission shaft drives a cutting attachment: a saw-chain and guide bar, a reciprocating saw blade, or a single-piece circular saw blade up to 205 mm in outside diameter.

The standard deals with all significant hazards, hazardous situations and hazardous events, with one exception. Electric shock from contact with overhead electric lines is outside it, apart from warnings and advice for inclusion in the instructions. It applies to machines made after its publication date, and brush cutters with a circular saw blade are excluded.

The entry shows the 2021 edition withdrawn on June 18, 2025, replacing the 2011 edition, and revised by ISO 11680:2025, which is published. The family of standards has a page of its own.

OSHA publication 3861

OSHA 3861, Electricity and Tree Care Work: A Deadly Combination (2016), is aimed at small business owners and front-line supervisors who do regular tree trimming rather than line-clearance trimming. It opens with three electrocutions. In the first, a landscaper was trimming branches from a portable work platform with a pole saw. The saw touched an energized overhead line. No co-workers or supervisors were on site, and he died later that day.

OSHA's safe work practices:

  • keeping at least 10 feet from overhead lines, and more than 10 feet where voltage to ground is over 50 kV, citing 29 CFR 1910.333(c)(3)(i);
  • no direct contact with an energized conductor, and no indirect contact through a limb or tool touching the line;
  • not relying solely on protective clothing;
  • assuming all lines are energized at all times.

The publication also lists survey of the area before work, an emergency plan and training in a language workers understand. Employers must provide rope that is free of moisture and contaminants and gives appropriate insulation when electrical hazards are present.

HSE on work near power lines

The Health and Safety Executive (HSE) page on working near power lines and cables sets a risk-based approach for arboricultural, aerial and ground work within 10 m of overhead power lines. The distance is measured at ground level, horizontally from below the nearest wire. Work more than 10 m away still counts if it could breach that distance, for example through falling trees, timber or debris.

HSE puts the first choice as working dead, with the power turned off. Any decision to work live must be justified, documented and meet Regulation 14 of the Electricity at Work Regulations. The advice of the network operator is to be sought where published guidance on distances conflicts.

Warnings in one maker's manual

One maker's operator's manual for a pole saw attachment, model series PSA1000 for use with a battery power head, prints these warnings.

Declared warnings, EGO PSA1000 pole saw attachment manual
TopicWording in the manual
Power linesDo not operate within 50 ft (15 m) of overhead electrical lines
Shock protectionThe unit is not built to protect against shock if it contacts overhead lines
Jammed chainThe bar, chain and aluminum pole can become electrically live
BystandersKeep at least 50 ft (15 m) away
LaddersDo not cut from a ladder
Head protectionUse head protection when operating overhead
WeatherNo use in bad weather, especially with a risk of lightning
UseNot for felling or bucking

The manual also calls for holding the pole pruner by insulated gripping surfaces only, because the chain may contact hidden wiring. It leaves safe distances from overhead lines to local regulations.

Three numbers

Distances printed for overhead lines
SourceDistance
OSHA 3861At least 10 feet; more above 50 kV
HSE10 m, risk-based approach inside it
Maker's manual50 ft (15 m)

Other guides cover pole saws near power lines and insulated pole saws.

Sources