Soil cells and suspended pavement: the types as city and agency documents describe them
Suspended pavement and soil cells hold the sidewalk up so the soil below stays loose. A US EPA guide, a Minnesota agency, Seattle and a British Columbia regional district describe the types and the soil volumes they cite.
Checked against the sources at the bottom of this page on October 19, 2026. Rules, fees and pay change: the source has the last word.
The US Environmental Protection Agency describes suspended pavement and structural cells as one system. A network of pillars, piles or structural cells carries the pavement and its loads. The soil below stays uncompacted for roots and for filtering stormwater runoff. Depending on engineering, such systems can carry vehicle loads.
The types
| Type | What the sources describe |
|---|---|
| Suspended pavement on columns or piles | The Minnesota Pollution Control Agency names Charlotte, North Carolina as the site of one of the earliest examples. A reinforced concrete sidewalk sat on poured concrete columns. The agency calls the design effective but labor-intensive, with exact column heights needed. |
| Modular soil cells | The Minnesota agency describes cells as a modular form of suspended pavement. They are a more recent, less labor-intensive technique. The modular design lets the volume be sized to each site, and underground utilities can be accommodated within these systems. The soil is protected from compaction, so a wide range of soils can be used. |
| Structural soil, rock-based | The EPA describes a gravel and clay loam mix. It is usually 70% to 80% angular gravel and 20% to 30% clay loam, with about 3% hydrogel. Void space is 20% to 25%. The Minnesota agency puts the soil share near 20% and the compaction at 95% Proctor density. |
| Structural soil, sand-based | The Minnesota agency describes an Amsterdam mix of medium coarse sand with organic matter and some clay. It is compacted to 70% to 80% Proctor density. It settled about 0.75 inch over three years, which the agency says may not be acceptable to many communities in the United States because of litigation risk from trip and fall hazards. |
Tree growth and soil volume in the EPA guide
The EPA guide EPA 841-B-13-001, September 2013, cites field studies by Smiley and others from 2006. Trees in uncompacted suspended pavement systems had better color, more root growth and grew faster and larger than trees in most other treatments, including structural soil. The guide also warns that the high rock volume in structural soil may keep a large tree from reaching full size.
The guide finds no universal standard for soil volume. It reports as widely accepted that a large tree, 16 inches at breast height, needs at least 1,000 cubic feet of uncompacted soil.
Drainage matters to the EPA. Underdrains may help where the base below is impervious and water ponds, because ponding may suffocate trees. Underground utilities can be placed around and even through suspended pavement. They should be protected from water and root penetration.
City and regional design documents
Seattle's Right-of-Way Improvements Manual, section 3.7, was last updated June 9, 2017. It gives 1,200 cubic feet of soil volume per tree as the industry standard for urban street trees. Where planting strips cannot supply it, the manual calls for structural soils and tree soil cells to add volume and connect root zones under paving. Structural soil needs four times the volume of tree soil cells to match the usable soil.
The Capital Regional District in British Columbia published Appendix G of its Green Stormwater Infrastructure Design Guidelines in Spring 2019. It describes structural soil cells as a system that transfers street and sidewalk loads below the growing medium through underground supports. A single tree makes a tree pit. Several trees make a tree trench.
- The District lists asphalt, concrete and unit pavers as surfaces cells can support, under sidewalks and roadways.
- It calls them quite costly and usually used only in heavily urbanized places with little room to separate trees from traffic.
- Design needs a qualified professional, a geotechnical investigation and a structural engineer for the supports. The load capacity named is AASHTO H20.
- The guideline sets a minimum of 30 cubic metres of soil per tree. It gives 21 to 28 cubic metres as the rooting volume trees in trenches usually need, and recommends a maximum of 3 trees per group of cells.
- A non-proprietary growing medium is listed by volume as 40% to 45% base soil, 45% to 50% coarse sand and 8% to 10% organic compost.
- With a bioretention soil mix, about 20% of the volume can store stormwater. The District's example is 200 cubic metres stored in 1,000 cubic metres of soil.
- Only limited utilities can sit in the growing medium, and utility providers must approve.
Cells need no regular maintenance in the District's account. Extra care is needed for work close to them. For utility access, the pavement is cut or the pavers lifted, the fabric is peeled back and the cells are removed by hand.
Where the sources differ
Seattle gives 1,200 cubic feet, about 34 cubic metres, per street tree. The EPA gives at least 1,000 cubic feet, about 28 cubic metres, for a 16-inch tree. The District gives a minimum of 30 cubic metres per tree. These are three separate figures from three separate documents.
The Minnesota agency lists as limits that soil cells are proprietary, so design manuals cannot prescribe them, that they need planning around utilities, and that cost may be a barrier.
Sources
- US Environmental Protection Agency, Stormwater to Street Trees, EPA 841-B-13-001, September 2013, read October 19, 2026
- Minnesota Pollution Control Agency, Minnesota Stormwater Manual, types of tree BMPs, read October 19, 2026
- Seattle Department of Transportation, Seattle Streets Illustrated, 3.7 Street Trees, last updated June 9, 2017, read October 19, 2026
- Capital Regional District, Green Stormwater Infrastructure Design Guidelines, Appendix G, structural soil cells with and without trees, Spring 2019, read October 19, 2026