Spark arrestors and equipment use in fire season: federal, California, Oregon and BC rules
California requires a spark arrester on hydrocarbon engines working wildland, and British Columbia requires one within 300 metres of forest. Oregon's IFPL levels confine power saws to 8 p.m. to 1 p.m. at level II.
Checked against the sources at the bottom of this page on October 19, 2026. Rules, fees and pay change: the source has the last word.
This page reports what the official source says. It is not legal advice: ask the office named here. Engine rules for fire season sit in four places: the Forest Service order power in 36 CFR 261.52, California Public Resources Code section 4442, British Columbia's Wildfire Act and Wildfire Regulation, and the Oregon Department of Forestry.
At a glance
| Place | Rule | What it says about engines |
|---|---|---|
| National forests | 36 CFR 261.52 | When an order provides, operating an internal combustion engine is prohibited |
| California | Public Resources Code 4442 | A hydrocarbon engine on forest, brush or grass land needs a spark arrester in working order |
| British Columbia | Wildfire Regulation, section 8 | An engine within 300 m of forest or grass land needs a spark arresting device built into the exhaust when a fire could start or spread |
| British Columbia | Wildfire Act, section 12 | The minister can prohibit or restrict activities and equipment in an area for a period |
| Oregon, west of the Cascades | Industrial Fire Precaution Levels | Four levels: fire season, limited shutdown, restricted shutdown, complete shutdown |
Forest Service orders
Section 261.52 of 36 CFR is headed "Fire". Its list applies only "when provided by an order". The list covers building or using a fire, using an explosive, smoking, entering an area, entering without a prescribed firefighting tool, operating an internal combustion engine, and welding or operating an open-flame torch. The text carries no spark arrester wording. The section was published at 89 FR 92816 on November 25, 2024.
California
Public Resources Code section 4442 bars anyone from operating an internal combustion engine that uses hydrocarbon fuels on forest-covered, brush-covered or grass-covered land. The bar lifts if the engine has a spark arrester, as subdivision (c) defines it, kept in effective working order. It also lifts if the engine is built and kept for fire prevention under section 4443.
Subdivision (c) defines a spark arrester as a device made of nonflammable materials that removes and retains carbon and other flammable particles over 0.0232 of an inch from the exhaust flow. A device qualified and rated by the United States Forest Service also meets the definition. Subdivision (b) bars mounting an arrester so that flames or heat from the exhaust can ignite flammable material.
The section sets out exceptions. Engines that drive trucks, truck tractors, buses and passenger vehicles, other than motorcycles, fall outside it when the exhaust has a muffler as the Vehicle Code defines it. A turbocharged engine falls outside it when all exhaust gas passes through the rotating turbine wheel, with no bypass to the air, and the turbocharger is in effective mechanical condition. Racing on a closed course under a permit has its own exception.
British Columbia
Section 8 of the Wildfire Regulation (B.C. Reg. 38/2005) covers engines other than railway engines. It bars operating an engine on forest land or grass land, or within 300 m of either, at a time when a fire could start or spread. Four conditions lift the bar. Necessary precautions are taken. The engine has a safe and effective spark arresting device that is an integral part of the exhaust system and in good repair. The exhaust system and muffler are within the manufacturer's specifications. An engine over 7.5 kW (10 hp) that is stationary or semi-permanent sits inside a fuel break.
The Regulation also lists "high risk activities". They include using fire- or spark-producing tools, cutting tools among them, grinding, mechanical land clearing, and clearing rights of way, including grass mowing. In a cutblock, operating a power saw and portable wood chipping are on the list. Section 6 requires the Fire Danger Class to be determined for a high risk activity on or after March 1 and before November 1, unless the area is snow covered. When a fire could start or spread, it requires the activity to follow Schedule 3, with a fire fighting hand tool for each person at the site and an adequate fire suppression system.
| Fire Danger Class | Restriction on high risk activities (Schedule 3) |
|---|---|
| III, moderate | After 3 consecutive days at III or greater, a fire watcher for at least one hour after the activity ends |
| IV, high | A fire watcher for at least 2 hours after the activity ends. After 3 consecutive days at IV, activity ceases between 1 p.m. local time and sunset |
| V, extreme | Activity ceases between 1 p.m. local time and sunset, with a fire watcher for at least 2 hours after. After 3 consecutive days at V, activity ceases all day |
The Wildfire Act is current to October 6, 2026, and the Regulation to October 13, 2026. Section 12 of the Act lets the minister prohibit or restrict activities, or the equipment, materials or substances used, in a specified area and period. The condition is that the minister considers them likely to cause or contribute to the spread of a fire. Subsection (2) bars carrying out an activity or using equipment against such an order. Subsection (4) lets the minister exempt a person in writing.
Oregon
The Oregon Department of Forestry imposes restrictions on public and work-related activities when fire season begins. Areas outside its protection, such as national forest, are linked to other agencies. The Department publishes separate maps for public and industrial restrictions, and the Industrial Fire Precaution Levels (IFPL) apply to land it protects west of the Cascades.
| Level | Power saws and spark-emitting work |
|---|---|
| I, fire season | Fire season requirements apply, with a firewatch unless waived |
| II, limited shutdown | Power saws, except at loading sites, may operate only between 8 p.m. and 1 p.m. The same window covers rotary head saw feller-bunchers, cable yarding, blasting, and welding, cutting or grinding of metal |
| III, restricted shutdown | Power saws on ground-based operations may run between 8 p.m. and 1 p.m. where equipment able to build fire line is immediately available. Power saws at loading sites and any other spark-emitting operation not mentioned may run in the same window |
| IV, complete shutdown | All operations are prohibited |
Waivers written in advance can cover any activity, power saws at loading sites or in felling and bucking among them, where extra prevention measures cut the fire risk. The IFPL sheet also lists a checklist item to clean out spark arrester ports.
Sources
- U.S. Code of Federal Regulations, 36 CFR 261.52 Fire, via eCFR, read October 19, 2026
- California Public Resources Code section 4442, public.law edition, read October 19, 2026
- British Columbia, Wildfire Act, SBC 2004 c. 31, current to October 6, 2026, read October 19, 2026
- British Columbia, Wildfire Regulation, B.C. Reg. 38/2005, current to October 13, 2026, read October 19, 2026
- Oregon Department of Forestry, Restrictions and closures, read October 19, 2026
- Oregon Department of Forestry, Industrial Fire Precaution Levels west of the Cascades (PDF), read October 19, 2026