Tie-in point selection criteria as each code words them
The NSW and NZ codes ask for anchor points strong enough for a fall and a rescue, set above the work. OSHA's memo prints 22.2 kN per employee, and WorkSafeBC requires the climbing plan to name the anchor.
Checked against the sources at the bottom of this page on October 15, 2026. Rules, fees and pay change: the source has the last word.
This page reports what the official source says. It is not legal advice: ask the office named here. It is not training and does not teach the work.
The criteria, source by source
| Source | What the text says about the anchor |
|---|---|
| HSE, United Kingdom | Strength. Each anchor point should be strong enough to support the climber, work equipment and any foreseeable loading. Number. Where possible, the system is attached to 2 anchor points that carry the load. |
| ICoP, United Kingdom | Choice. A proficient operator picks anchor points that will not be compromised by tree condition or by the work, and evaluates how much load they can bear (3.3.5.1). Strength. The anchor point of a personal fall protection system must be unquestionably reliable and able to withstand any foreseeable loading throughout the task (3.8.6). Backup. The backup should be attached to an independent anchor where possible. Temporary devices. Slings and savers must be made to the standard for temporary anchors, must not slip up or down the stem, and must have a minimum breaking strength of at least 18 kN (3.10.6.2). |
| SafeWork NSW, 4.3 and 4.9, New South Wales | Location. Above the work area or as close as possible, giving the safest working angle and position, chosen so a slip or fall does not swing the worker toward or over electrical conductors. Strength. Structurally sound and able to support the force of a fall, two people and possible rescue loads, tested by proof loading before climbing where practicable. Tree. Defects are checked. For natural anchors the junction angle, the tree's condition and species, and a weight test count, and some stems are too small to use. Where no natural anchor suits, other access or artificial anchors are used. Number. When operating cutting equipment, two points of attachment, preferably from independent anchor points. |
| WorkSafe NZ code, 3.2.2 and 3.1.6, New Zealand | Location. Above the work area, with the line passed around the main leader or an upright branch. A false crotch may be used instead of or where there is no natural crotch. Strength. Enough to take the climber's weight and equipment and that of a potential rescuer, and to withstand dynamic forces. Number. The climber is attached to a suitable anchor point at all times, with no more than 0.5 metres of slack. A second anchor point is needed when cutting, and supplementary anchor points where a fall or swing that may cause injury is possible. |
| WorkSafeBC, 26.12.0.3 and 26.12.0.4, British Columbia | Plan. The tree-climbing plan names the type and location of the initial anchor point. Check. The arborist assesses each anchor point or point of securement as suitable for the loads before using it. Number. Each climbing line uses at least one anchor point, and independent ones if practicable, and sits so the line cannot move away from the anchor though it may slide through. |
| OSHA enforcement memo, June 24, 2021, United States | Strength. Under 29 CFR 1910.140, paragraph (c)(13), anchorages used for climbing in trees support at least 5,000 pounds (22.2 kN) per attached employee. The alternative is an anchorage designed, installed and used under a qualified person, in a complete system with a safety factor of at least two. Ground check. The memo says no citation issues where a qualified person inspects the anchor from the ground and the employer follows ANSI Z133-2017 section 8.1.11. |
Where the sources differ
Three sources print a strength figure: 22.2 kN per employee for OSHA, 18 kN for temporary anchor devices in the ICoP, and 22 kN for each component of a false crotch in the WorkSafe NZ glossary. The NSW code and the NZ text on anchor points describe the load instead, a fall, rescue loads and dynamic forces. HSE and the ICoP speak of foreseeable loading. WorkSafe NZ and SafeWork NSW both place the anchor above the work area, and HSE's page does not.
The definitions
The ICoP defines an anchor point as a point of attachment for personal fall protection systems or anchor devices, providing a means of support or suspension. SafeWork NSW defines it as any fork formed by the junction of two branches or a branch and the trunk that can be used safely by a climber, or a device installed in a tree for the purpose. Fuller word-by-word comparisons are in the table of climbing words by code. Second attachments are covered in the guide to tie-in and second attachment rules.
Credits: HSE wording is adapted from pages licensed under the Open Government Licence v3.0. SafeWork NSW text is adapted from the Tree works code of practice (March 2026), copyright State of New South Wales (SafeWork NSW), licensed under Creative Commons Attribution 4.0; changes were made, because the text is summarised and reworded. WorkSafe New Zealand material is summarised from its Approved Code of Practice for Safety and Health in Arboriculture, with the source acknowledged.
Sources
- HSE, Tree climbing, tree work safety topics, read October 15, 2026
- Arboricultural Association, Industry Code of Practice for Arboriculture: Tree Work at Height (ICoP), second edition, May 2020, read October 15, 2026
- SafeWork NSW, Tree works code of practice, March 2026, read October 15, 2026
- WorkSafe New Zealand, Approved Code of Practice for Safety and Health in Arboriculture, read October 15, 2026
- WorkSafeBC, OHS Regulation Part 26 Forestry operations and similar activities, read October 15, 2026
- OSHA, Inspection Guidance for Tree Care and Tree Removal Operations, enforcement memorandum, June 24, 2021, read October 15, 2026