Washington State tree work rules: WAC 296-54 and 296-45
Washington addresses work in trees in WAC 296-54 for logging and WAC 296-45 for electric power. Section 296-45-455 of the second chapter covers line-clearance tree trimming.
Checked against the sources at the bottom of this page on October 21, 2026. Rules, fees and pay change: the source has the last word.
This page reports what the official source says. It is not legal advice: ask the office named here. Both chapters belong to the Washington Administrative Code (WAC) and cite chapter 49.17 RCW as their statutory authority. Other states and provinces are in the tree work rules guide.
Two chapters, two kinds of work
| Chapter | Title | Last update on the Legislature site |
|---|---|---|
| WAC 296-54 | Safety standards, logging operations | August 22, 2017 |
| WAC 296-45 | Electric power generation, transmission, and distribution | January 6, 2026 |
WAC 296-54: logging operations
Section 296-54-501 sets the scope. The chapter establishes safety practices for all types of logging operations, log road construction and other similar activities. It does not apply to log handling at sawmills, plywood mills, pulp mills or other manufacturing operations. The chapter sets minimum safety requirements for the logging industry.
Logging is also covered by the general safety standards in chapter 296-24, the occupational health standards in chapter 296-62 and the core rules in chapter 296-800. The explosives chapter, 296-52, applies when explosives are used in logging.
The chapter index lists the sections that touch work in and on trees:
- personal protective equipment, with separate sections for head, eye and face, hearing, hand, respiratory, leg and foot protection and high visibility clothing (296-54-511);
- overhead electrical lines clearance (296-54-529) and chain saws (296-54-537);
- falling and bucking, with separate sections for falling, bucking, danger trees, and springboards and tree jacking (296-54-539 to 296-54-53940);
- tree pulling (296-54-541) and mechanized falling (296-54-543);
- climbing equipment and passline (296-54-545).
The index also carries first-aid training and first-aid kit sections, an accident prevention program section, and a chain shot awareness and prevention series (296-54-520 and its sub-sections). Appendix 3 lists industry consensus standards.
WAC 296-45: where line-clearance tree trimming sits
Chapter 296-45 covers the operation, maintenance and construction of electric power generation, control, transformation, transmission and distribution lines and equipment. Section 296-45-015(1)(e) brings in line-clearance tree-trimming operations and splits them by who does the work.
- For qualified electrical employees, the chapter applies except WAC 296-45-455.
- For line-clearance tree trimmers who are not qualified electrical employees, the listed sections apply: 296-45-065, 296-45-067, 296-45-125, 296-45-135, 296-45-255, 296-45-315, 296-45-375, and 296-45-455 through 296-45-45530.
The scope section defines a qualified electrical employee as someone knowledgeable in the construction and operation of the electric power equipment involved, along with the associated hazards. Work not covered falls under chapters 296-24, 296-27, 296-62, 296-155 and 296-800, among others the section lists.
Section 296-45-015(9) states that "must" makes a provision mandatory, while "should", "may" and "it is recommended" mark provisions that are not mandatory.
The line-clearance section, WAC 296-45-455
Section 296-45-455 is titled line-clearance tree-trimming operations. It gives additional requirements for the operations and the equipment used, and does not apply to qualified electrical employees. Its subsections, as filed in WSR 19-13-083 effective August 1, 2019, say the following.
| Subsection | Requirement |
|---|---|
| (1) | Before an employee climbs, enters or works around any tree, the nominal voltage of power lines posing a hazard must be determined, or the maximum voltage to be met taken as the voltage for all lines |
| (2) | A second line-clearance tree trimmer must be within normal, unassisted voice communication in three cases: a trimmer approaches closer than 10 feet (305 cm) to a conductor or apparatus energized above 600 volts; branches being removed are closer to such lines than the Table 2 distances; or roping is necessary near such conductors |
| (3) | Minimum approach distances from energized conductors are those in Table 2 of WAC 296-45-325 |
| (4) | Branches contacting exposed energized conductors, or within the Table 2 distances, may be removed only with insulating equipment |
| (5) | Ladders, platforms and aerial devices must not be brought closer to an energized part than the Table 2 distances |
| (6) | The work cannot be performed when adverse weather makes it hazardous despite the required practices; storm and emergency work needs workers trained in its special hazards |
| (7) | A trimmer may climb between a basket and a tree if tied into the tree throughout and the employer can show it is the safest way to do the work |
A note to subsection (4) treats a tool as insulated if it is made of a material the employer can show meets WAC 296-45-305(1) and is clean and dry. A note to subsection (6) names thunderstorms in the immediate vicinity, high winds, snow storms and ice storms as examples presumed too hazardous.
Equipment sections under 296-45-455
Six sections follow 296-45-455 in the chapter index: brush chippers (296-45-45505), sprayers and related equipment (296-45-45510), stump cutters (296-45-45515), backpack power units for use in pruning and clearing (296-45-45520), rope (296-45-45525) and fall protection (296-45-45530). Chapter 296-45 also holds sections on gasoline engine power chain saws (296-45-295), overhead lines (296-45-385) and mechanical equipment including aerial manlift equipment (296-45-375).
Sources
- Washington State Legislature, Chapter 296-54 WAC, Safety standards, logging operations, last update August 22, 2017, read October 21, 2026
- Washington State Legislature, WAC 296-54-501, Scope and application, read October 21, 2026
- Washington State Legislature, Chapter 296-45 WAC, Electric power generation, transmission, and distribution, last update January 6, 2026, read October 21, 2026
- Washington State Legislature, WAC 296-45-015, Scope and application, read October 21, 2026
- Washington State Legislature, WAC 296-45-455, Line-clearance tree-trimming operations, read October 21, 2026