ArbNation Join free

Anchor points in the tree climbing codes: choosing and checking them

The ICoP, the SafeWork NSW code, the New Zealand code, HSE and WorkSafeBC all name what an anchor point has to be. Only the NSW code asks for proof loading and a weight test, and only the ICoP gives an anchor strength figure.

Checked against the sources at the bottom of this page on October 19, 2026. Rules, fees and pay change: the source has the last word.

The named codes and training bodies are described here as published. It is not training and does not teach the work.

Credits: SafeWork NSW text is adapted from the Tree works code of practice (March 2026), copyright State of New South Wales (SafeWork NSW), licensed under Creative Commons Attribution 4.0; changes were made, because the text is summarised and reworded. WorkSafe New Zealand material is summarised from its Approved Code of Practice for Safety and Health in Arboriculture (November 2012), with the source acknowledged. HSE text is adapted under the Open Government Licence v3.0.

What an anchor point is

The ICoP defines an anchor point as a point of attachment for personal fall protection systems or anchor devices, giving a means of support or suspension. The SafeWork NSW code defines it as a fork formed by two branches, or a branch and the trunk, that a climber can use safely for the climbing or lowering rope. That is a natural anchor point. A device installed in a tree, such as a pulley and sling assembly, is an artificial one.

The wording in each code

SourceSelecting and checking the anchor
ICoP (United Kingdom), 3.8.6 and 3.3.5.1The anchor point of a personal fall protection system must be unquestionably reliable. It must withstand any foreseeable loading throughout the task. The backup is attached to an independent anchor where possible. Operators must be able to select anchors that tree condition or the work will not compromise, and to evaluate their load bearing capacity.
SafeWork NSW code, 4.3 (Australia)Anchors are above the work area or as close as possible to it. They are structurally sound and able to take the force of a fall, two people and possible rescue loads. They keep the worker from swinging toward conductors or other hazards. The code asks for proof loading and testing before climbing, where practicable. For natural anchors it asks whether a weight test has been completed and whether the rope runs freely.
WorkSafe NZ code, 3.2.2 (New Zealand)Anchor points should be above the work area. They shall take the climber's weight and equipment and that of a potential rescuer, and withstand dynamic forces. Supplementary anchors are used where a fall or swing that may cause injury is possible. No test is named.
HSE tree climbing page (United Kingdom)Where possible the system is attached to two load bearing anchor points. Each should support the climber, the work equipment and any foreseeable loading. Where a backup is not reasonably practicable, choosing reliable anchor points is listed among the measures against the positioning system failing.
WorkSafeBC Part 26, 26.12.0.4 (British Columbia)The climbing line uses at least one anchor point or other point of securement, and independent ones if practicable. The line is positioned so that it will not move away from the anchor, though it may slide through. The climber must assess and determine that each anchor point suits the loads before using it.
AHCARB319 (Australia)The unit asks for anchor points chosen for load bearing and access, and for low-risk anchors installed with throw lines. Remotely installed anchors are inspected and tested as secure before use.

Natural anchors in the NSW code

The NSW code lists extra points for natural anchors. Junctions should have enough angle, or be captive, so that the rope cannot walk toward the branch tip. A friction saver or anchor sling reduces friction and rope walking.

The strength, condition and species of the tree count, and the code names coral trees, willows and poplars as examples. On smaller junctions the climber passes the rope around the vertical stem or the larger of two stems. Some stems are too small to serve.

Where a tree has no suitable natural anchor in the place wanted, the code points to other access methods or artificial anchors. It names palms and similar trees as an example.

Artificial and temporary anchors in the ICoP

The ICoP's section 3.10.6.2 covers anchor devices. A temporary anchor device is an artificial anchor point, as opposed to the natural structure of the tree, and tape slings and cambium savers are given as examples. It must be made to the standard for temporary anchors, and it must not slip up or down the stem. Its minimum breaking strength is at least 18 kN.

Machinery and vehicles can serve as artificial anchors, with a basal tie-off for single rope technique as the example. The ICoP asks for enough mass to be unquestionably reliable, enough friction against the ground, no damage from the anchoring and no movement while in use.

Figures that are missing

Only the ICoP gives an anchor strength figure, 18 kN for a temporary anchor device. No source opened here gives a proof-load figure for a natural anchor in a tree. The NSW code asks for proof loading and a weight test without a number.

Sources