Fire extinguishers on tree crew vehicles: OSHA 1910.157, FMCSA 393.95 and UK fire law
OSHA's 1910.157 covers extinguishers for employees but does not mention vehicles. FMCSA's 393.95 sets a minimum rating for each truck, and OSHA's tree care page recommends considering extinguishers in work vehicles.
Checked against the sources at the bottom of this page on October 16, 2026. Rules, fees and pay change: the source has the last word.
This page reports what the official source says. It is not legal advice: ask the office named here. Three United States texts apply to extinguishers: OSHA's portable fire extinguisher standard, 29 CFR 1910.157, the Federal Motor Carrier Safety Regulations section 49 CFR 393.95 on emergency equipment, and OSHA's tree care hazards page. The United Kingdom text is the Regulatory Reform (Fire Safety) Order 2005.
At a glance
| Text | Where it reaches | What it requires or recommends |
|---|---|---|
| 29 CFR 1910.157 | Portable extinguishers provided for the use of employees | Selection, placement, inspection, maintenance, testing and training duties on the employer. The text does not mention vehicles |
| 49 CFR 393.95(a) | Each truck, truck tractor and bus, except those towed in driveaway-towaway operations | One extinguisher rated 5 B:C or more, or two rated 4 B:C or more each. 10 B:C or more for placarded hazardous materials |
| OSHA tree care hazards page | Tree care shops and work vehicles | Recommends consideration of extinguishers in work vehicles as appropriate |
| Fire Safety Order 2005, article 13 | Premises in England and Wales | Appropriate fire-fighting equipment where necessary. Vehicles licensed under the Vehicle Excise and Registration Act 1994 fall outside the Order (article 6) |
29 CFR 1910.157
Section 1910.157 applies to the placement, use, maintenance and testing of portable fire extinguishers provided for the use of employees. Paragraph (c) requires the employer to provide the extinguishers and mount, locate and identify them so employees can reach them without possible injury. Only approved extinguishers count, and they must be kept fully charged, operable and in their designated places except during use.
Paragraph (d) bases selection and distribution on the classes of anticipated workplace fires and the size and degree of hazard. For Class A fires the travel distance to an extinguisher is 75 feet or less. For Class B fires it is 50 feet or less from the hazard area.
Paragraph (e) makes the employer responsible for inspection, maintenance and testing. Extinguishers are visually inspected monthly and get an annual maintenance check, and the employer records the annual date. Paragraph (f) sets hydrostatic test intervals in Table L-1, five years for several types and twelve years for others. Paragraph (g) requires an education program on initial employment and at least annually.
Paragraph (b)(1) exempts an employer from the section when a written fire safety policy requires immediate and total evacuation on an alarm, meets the emergency action and fire prevention plan sections, and no extinguishers are available in the workplace. The text of the section does not mention vehicles.
49 CFR 393.95
Section 393.95 is headed Emergency equipment on all power units. It states that each truck, truck tractor and bus, except those towed in driveaway-towaway operations, must be equipped as set out. The text gives no weight threshold of its own.
A power unit that carries hazardous materials in a quantity that requires placarding needs an extinguisher with an Underwriters' Laboratories rating of 10 B:C or more. Any other power unit needs either one extinguisher rated 5 B:C or more, or two rated 4 B:C or more each.
The manufacturer must label or mark each extinguisher with its rating. It must be designed, constructed and maintained so that a person can see whether it is fully charged. It must be filled, readily accessible and securely mounted against sliding, rolling or vertical movement. The agent must not need protection from freezing and must meet the toxicity provisions of EPA's Significant New Alternatives Policy regulations.
OSHA's tree care hazards page
OSHA's tree care hazards and solutions page lists common shop hazards and tree care considerations. One item is fire hazards in shop areas, with references to 1910.106 and 1910.157. Another is adequate fire extinguishers under 1910.157 and first aid kits under 1910.151 in the shop. It adds that it is recommended that consideration be taken to include extinguishers in work vehicles as appropriate.
United Kingdom: Fire Safety Order 2005
Article 13 of the Regulatory Reform (Fire Safety) Order 2005 is headed Fire-fighting and fire detection and is marked as applying in England and Wales. Where necessary, the responsible person must "ensure" that the premises are equipped, to the extent appropriate, with fire-fighting equipment, fire detectors and alarms. Non-automatic fire-fighting equipment must be easily accessible, simple to use and indicated by signs.
What is appropriate depends on the dimensions and use of the premises, the equipment on them, the properties of substances present and the maximum number of people there at one time. The responsible person also nominates competent persons to implement fire-fighting measures.
Article 6 excludes several things from the Order. They include fields, woods or other land of an agricultural or forestry undertaking that is outside a building and away from the main buildings. They also include a trailer or semi-trailer used as a means of transport, and a vehicle licensed under the Vehicle Excise and Registration Act 1994 or exempted from duty under it.
Sources
- US Government, 29 CFR 1910.157 Portable fire extinguishers, eCFR, read October 16, 2026
- US Government, 49 CFR 393.95 Emergency equipment on all power units, eCFR, read October 16, 2026
- OSHA, Tree Care Industry: Hazards and Solutions, common shop hazards, read October 16, 2026
- UK Government, Regulatory Reform (Fire Safety) Order 2005, article 13, legislation.gov.uk, read October 16, 2026
- UK Government, Regulatory Reform (Fire Safety) Order 2005, article 6, legislation.gov.uk, read October 16, 2026