ArbNation Join free

Friction hitch tests published by industry: the Treevolution report and the Tuscia paper

Treevolution pulled and dropped ten hitch types on a UK test rig, and the University of Tuscia published 36 tensile tests in 2021. Both are open to read.

Checked against the sources at the bottom of this page on October 19, 2026. Rules, fees and pay change: the source has the last word.

Two published test reports and the UK industry code are described here as published. It is not training and does not teach the work.

The Treevolution report

Paolo Bavaresco of Treevolution wrote "Ropes and Friction Hitches used in Tree Climbing Operations", a 71-page report on UK practice. The contract was awarded in March 2002. Tests ran on rigs at the National Access and Rescue Centre. The pull rig had about one metre of travel. The drop rig hung from a nine metre gantry with a 100 kg mass.

The report states that no earlier research had measured hitch strength in the doubled rope system arborists use. It tested the 4-wrap and 6-wrap Prusik, 5-wrap Swabisch, 5-wrap Distel, 4-wrap Klemheist, 4-wrap Blake's, 4-wrap Tautline, 6-wrap Helical and the 6-wrap and 7-wrap Valdotain tresse.

Results as the report prints them
TestPrinted result
Doubled rope pull, new control set-upPeak force from 2223 kg to 3567 kg, average 3086 kg. The lowest value is a safety factor of about 22:1 on an assumed 100 kg climber.
Doubled rope pull, separate carabinersSafety factors from 26:1 to 36:1. The rope termination was the weakest link, not the hitch.
Single rope pullLowest control result just under 19:1, with the 6-wrap Prusik. The lifeline bowline failed. A 6 mm Dyneema cord failed at 1376 kg, within the friction hitch.
Doubled rope drop, 25 cm slack in each legAbout 683 kg of fall force. With slack in one leg only, the average was 565 kg.
Doubled rope drop, fall factor 1Average 770 kg. The hitches slipped about 3 cm and one welded to the rope.
Doubled rope drop, fall factor 2Average 1115 kg. The hitches slipped about 15 cm and two welded to the rope.
Single rope drop, fall factors 1 and 2Averages of 662 kg and 679 kg.

The report also tested an 18-month-old, heavily used single-braid rope. Knotted strength fell by about 40 percent against the new control rope. The weakest result was 1770 kg, a safety factor of 17:1.

The report lists its own limits. Cords were new and tested once. The pull rig stopped short of a failure on some hitches. The drop rig was nine metres tall, which the authors say leaves less rope to absorb a fall than most trees would.

Treevolution recommendations

The report recommends a minimum safety factor of 14:1 and ideally 20:1. It recommends friction cord of at least 10 mm, polyester or nylon, with a minimum strength of 1700 kg. It does not recommend 6 mm cord.

It rejects any cord that is not synthetic or that melts below 350 degrees Fahrenheit, which rules out Dyneema and polypropylene in its view. It suggests work ropes retire after two to three years and friction cords after three months of normal use.

The University of Tuscia paper

Bianchini, Picchio, Colantoni, Scotolati, Di Stefano and Cecchini published "Tensile Strength of Ropes and Friction Hitch Used in Tree Climbing Work" in Forests, volume 12, article 1457, on October 26, 2021. The journal is open access under a CC BY licence.

The team ran 36 tests on a traction bench. They used two work ropes, 11 mm and 13 mm, with a Prusik and a Valdotain tresse tied from 8 mm cord. Each combination had nine pulls. Readings came every 50 mm over a 250 mm stroke.

  • Maximum load was 18.7 kN, maximum slip 9.6 cm and maximum rope diameter change 3 mm.
  • The highest mean loads were 11.9 kN and 15.1 kN for the Prusik on the two ropes, and 9.3 kN and 8.6 kN for the Valdotain.
  • The Prusik gripped harder and slipped less. Mean slip was 1.75 cm for the Prusik and 3.17 cm for the Valdotain.
  • Knot type drove load and slip. Rope type drove the change in rope diameter.
  • Rope surface temperature rose by 3.1 to 6.8 degrees Celsius.

The authors call the work preliminary. They say their aim was not to name the best knot. They state that a hitch tied by the climber has no European certification, unlike mechanical rope clamps and descenders.

What the codes print on friction cord

CodeWording
ICoP, Tree Work at Height, Edition 2, May 2020, clause 3.10.6.8Friction cord is suitable for its use by diameter and construction, from materials resistant to the abrasion and temperatures of work and rescue. Its attachment must not stop the hitch locking positively and reliably. The clause sets no diameter or strength.
WorkSafe New Zealand, approved code of practice, 2012, section 3.2Friction hitches should use cordage of at least 70 percent of the climbing line diameter. Climbers consider fibre type, construction and diameter because they affect holding, abrasion resistance, heat and working life.

Sources