The National Electrical Safety Code and vegetation: 2023 edition, Texas and California

The 2023 National Electrical Safety Code is IEEE C2-2023, published in August 2022. Texas rule 25.96 names Section 218 of the Code, and California's General Order 95 has its own Rule 35 on vegetation.

Checked against the sources at the bottom of this page on October 21, 2026. Rules, fees and pay change: the source has the last word.

This page reports what the official source says. It is not legal advice: ask the office named here. The standard itself is paywalled, so what follows is the published scope, the edition history and two state rules that deal with vegetation near lines.

The 2023 edition

IEEE lists the 2023 National Electrical Safety Code as IEEE C2-2023, an active standard. It was published on August 1, 2022 and supersedes C2-2017. IEEE sells it by purchase or by subscription, and the Finnish standards body SFS carries the same edition as a catalogue entry dated August 2022.

IEEE describes the Code as covering practical safeguarding of persons during the installation, operation or maintenance of three things: electric supply stations, overhead supply and communications lines, and underground or buried supply and communication cables. It also includes work rules for operating supply and communications lines and equipment. The Code is made up of the introduction, definitions, grounding rules, lists of referenced and bibliographic documents, and Parts 1, 2, 3 and 4.

The IEEE description does not mention vegetation, trees or Rule 218. Neither catalogue entry prints the text of any rule, so the wording of Section 218 is not available from them.

Texas: Section 218 named in a commission rule

The Public Utility Commission of Texas rule at 16 Texas Administrative Code section 25.96 covers an electric utility's distribution assets. It defines those as facilities operating at less than 60 kilovolts, excluding substations, underground facilities and service drops.

Subsection (d) lists three industry standards. One is ANSI Z133.1 on arboricultural operations and pruning. Another is ANSI A300, Parts 1, 7 and 9, on pruning, integrated vegetation management for utility rights-of-way and tree risk assessment. The third is "National Electrical Safety Code Section 218, or successor standard". Where a utility's vegetation management policies do not conform to a mandatory provision of any of the three, the utility gives a brief explanation of the deviation in its Vegetation Management Report.

The rule also sets the reporting calendar. Each utility keeps a Vegetation Management Plan and reviews it by December 31 each year, and files its Vegetation Management Report with the commission by May 1 each year. The Texas text says its provisions took effect on January 2, 2013. It does not name an edition year of the Code.

California: Rule 35 of General Order 95

The California Public Utilities Commission keeps its own overhead line rules in General Order 95. Rule 35, Vegetation Management, does not mention the National Electrical Safety Code. It applies to all overhead electrical supply and communication facilities covered by the General Order, including those on lands owned and maintained by California state and local agencies.

The rule ties clearances to Table 1, Cases 13 and 14, and refers to Appendix E for tree trimming guidelines. Some of its main parts:

  • A company with actual knowledge of dead, rotten or diseased trees, or portions of trees, that overhang or lean toward a span and may fall into it should have them removed.
  • Circuits energized at 750 volts or less, including service drops, should be kept clear of vegetation in new construction and in rebuilds or repairs, whenever practicable.
  • A circuit at 750 volts or less that shows strain or abrasion from vegetation contact is to be corrected by reducing tension, rearranging or replacing the conductor, pruning, or adding mechanical protection.
  • Contact between vegetation and a conductor does not by itself make a line nonconforming.

Rule 35 carries four exceptions. The first covers conductors under 60,000 volts where trimming or removal is not practicable and the conductor is separated from the tree. The second covers a company that made a good faith effort to get permission and was refused. That effort consists of current documentation of an attempted personal contact and a written communication. The third recognises unusual circumstances beyond the utility's control. The fourth was added by Decision No. 9710056. It exempts mature trees whose trunks and major limbs sit more than six inches from primary distribution conductors but inside the Table 1 clearance, and the utility bears the risk of deciding whether it applies.

Gaps in the sources

None of the four records lists which states adopt which edition of the Code. Texas and California are the two examples with a printed rule, and only Texas names the Code.