Split tails, hitch cord eye-to-eye and stopper knots: what NSW, NZ and the ICoP say

SafeWork NSW names the stopper knot and the barrel knot as knots not to use. The NZ code puts the strength loss from a knot at up to 50 percent. The ICoP defines a termination as a knot, a splice or a stitched eye.

Checked against the sources at the bottom of this page on October 19, 2026. Rules, fees and pay change: the source has the last word.

The named codes and training bodies are described here as published. It is not training and does not teach the work. Three documents are covered. They are the SafeWork NSW Tree works code of practice (March 2026) and the WorkSafe New Zealand Approved Code of Practice for Safety and Health in Arboriculture (November 2012). The third is the ICoP for Arboriculture: Tree Work at Height (Edition 2, May 2020).

The terms "split tail" and "eye-to-eye" for hitch cord appear in none of the three. The wording below is the closest each document comes.

Terms

DocumentTermDefinition or wording
ICoPTerminationThe end of a piece of rope. It can be a knot, a splice, a stitched eye or a combination of these
ICoPHitch (friction)Knots and hitches used to control ascent or descent, or to keep position on the rope, that self lock when released
ICoPFriction cordA component of a personal fall protection system used in knots and hitches to control ascent, descent or position on the rope

The ICoP on cord and terminations

Section 3.10.6.8 sets figures for rope. When new, rope with a termination has a minimum breaking strength (MBS) of 15 kN, and rope without a termination has an MBS of 22 kN. Splices in rope are formed only by the manufacturer, or with their consent against validated performance criteria and independent verification.

For friction hitch cord, the same section lists two criteria. The cord is suitable for its use by diameter and construction, from materials resistant to the abrasion and temperatures met in work and rescue. The way it is attached to a connector or placed in a system does not restrict the hitch, which locks positively and reliably when advanced or during descent.

Section 3.3.5.3 lists what operators in rigging operations must be able to do. The list includes understanding strength loss due to knots within cordage components.

The NSW code

Section 4.9 lists knots that should not be used in fall prevention. They are knots that are insecure if tied incorrectly, knots that require a second knot for security, and knots that creep or loosen under load. The code gives the stopper knot and the barrel knot as examples of the last group.

Section 4.7 covers prusik loops and other friction knots. They should be compatible with the climbing rope, formed using fit for purpose rope and an appropriate length, tested at ground level before first use in a tree, and inspected before and after each use for heat and abrasion damage.

The crane clause, section 6.6, asks for systems that prevent the use of knots or hitches known to slip, loosen or roll under load. Section 8.3 says a lowering rope should be free of intermediate knots, twists and tangles.

The NZ code

Section 3.2.4 says climbing lines shall be free of joining splices or knots. Spliced eyes or end splices shall follow the rope manufacturer's instructions. The section adds that knots can weaken a rope by up to 50 percent of its breaking strength.

The same section says that, where appropriate, a knot should be placed at the end of the line as a back-up to stop the climber descending off the end. The NSW code, by contrast, names the stopper knot among knots it does not want used.

Section 3.2.5 says friction hitches should be tied with a minimum cordage diameter of 70 percent of the climbing line in use. Climbers shall consider fibre type, construction and cordage diameter when selecting a friction hitch.

The only eye-to-eye wording in the NZ code is in the wire rope part of section 3.4.6. It says eye-to-eye splices shall not be made in any pulling or lifting rope, and only long splices or butt splices are to be used in joining such ropes.

Where the wording differs

  • Stopper or end knot. The ICoP does not name it. NSW names stopper and barrel knots among knots not to use. NZ puts a knot at the end of the line as a back-up, where appropriate.
  • Knot strength loss. ICoP section 3.3.5.3 names it for rigging operators. NSW gives no figure. NZ gives up to 50 percent of breaking strength.
  • Hitch cord size. The ICoP asks for cord suitable by diameter and construction. NSW asks for cord compatible with the climbing rope. NZ asks for at least 70 percent of the climbing line diameter.
  • Splices. The ICoP has them made by the manufacturer or with consent. NSW does not address them. NZ has them follow the rope manufacturer's instructions.